Willem Jan Palenstijn
Willem Jan Palenstijn
Verified email at cwi.nl
Title
Cited by
Cited by
Year
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography
W Van Aarle, WJ Palenstijn, J De Beenhouwer, T Altantzis, S Bals, ...
Ultramicroscopy 157, 35-47, 2015
4522015
Fast and flexible X-ray tomography using the ASTRA toolbox
W Van Aarle, WJ Palenstijn, J Cant, E Janssens, F Bleichrodt, ...
Optics express 24 (22), 25129-25147, 2016
3432016
Performance improvements for iterative electron tomography reconstruction using graphics processing units (GPUs)
WJ Palenstijn, KJ Batenburg, J Sijbers
Journal of structural biology 176 (2), 250-253, 2011
2752011
Advances in X-ray diffraction contrast tomography: flexibility in the setup geometry and application to multiphase materials
P Reischig, A King, L Nervo, N Viganó, Y Guilhem, WJ Palenstijn, ...
Journal of Applied Crystallography 46 (2), 297-311, 2013
1082013
The ASTRA tomography toolbox
WJ Palenstijn, KJ Batenburg, J Sijbers
13th International Conference on Computational and Mathematical Methods in …, 2013
692013
Integration of TomoPy and the ASTRA toolbox for advanced processing and reconstruction of tomographic synchrotron data
DM Pelt, D Gürsoy, WJ Palenstijn, J Sijbers, F De Carlo, KJ Batenburg
Journal of synchrotron radiation 23 (3), 842-849, 2016
612016
TVR-DART: A more robust algorithm for discrete tomography from limited projection data with automated gray value estimation
X Zhuge, WJ Palenstijn, KJ Batenburg
IEEE Transactions on Image Processing 25 (1), 455-468, 2015
442015
Quantitative 3D analysis of huge nanoparticle assemblies
D Zanaga, F Bleichrodt, T Altantzis, N Winckelmans, WJ Palenstijn, ...
Nanoscale 8 (1), 292-299, 2016
352016
Dynamic angle selection in binary tomography
KJ Batenburg, WJ Palenstijn, P Balázs, J Sijbers
Computer Vision and Image Understanding 117 (4), 306-318, 2013
292013
Easy implementation of advanced tomography algorithms using the ASTRA toolbox with Spot operators
F Bleichrodt, T van Leeuwen, WJ Palenstijn, W van Aarle, J Sijbers, ...
Numerical algorithms 71 (3), 673-697, 2016
252016
A distributed ASTRA toolbox
WJ Palenstijn, J Bédorf, J Sijbers, KJ Batenburg
Advanced structural and chemical imaging 2 (1), 1-13, 2016
192016
Constructing simple nonograms of varying difficulty
KJ Batenburg, S Henstra, WA Kosters, WJ Palenstijn
Pure Mathematics and Applications (Pu. MA) 20, 1-15, 2009
172009
Point spread function based image reconstruction in optical projection tomography
AK Trull, J Van Der Horst, WJ Palenstijn, LJ Van Vliet, T Van Leeuwen, ...
Physics in Medicine & Biology 62 (19), 7784, 2017
162017
A new exam timetabling algorithm
KJ Batenburg, WJ Palenstijn
Proceedings of BNAIC 3, 2003
132003
A distributed SIRT implementation for the ASTRA toolbox
WJ Palenstijn, J Bédorf, KJ Batenburg
Proc. Fully Three-Dimensional Image Reconstruct. Radiol. Nucl. Med, 166-169, 2015
112015
Modeling blurring effects due to continuous gantry rotation: Application to region of interest tomography
J Cant, WJ Palenstijn, G Behiels, J Sijbers
Medical Physics 42 (5), 2709-2717, 2015
112015
Real-time quasi-3D tomographic reconstruction
JW Buurlage, H Kohr, WJ Palenstijn, KJ Batenburg
Measurement Science and Technology 29 (6), 064005, 2018
102018
Radicals in arithmetic
WJ Palenstijn
University of Leiden, 2014
92014
Explorative imaging and its implementation at the FleX-ray laboratory
SB Coban, F Lucka, WJ Palenstijn, D Van Loo, KJ Batenburg
Journal of Imaging 6 (4), 18, 2020
82020
EDS tomographic reconstruction regularized by total nuclear variation joined with HAADF-STEM tomography
Z Zhong, WJ Palenstijn, J Adler, KJ Batenburg
Ultramicroscopy 191, 34-43, 2018
72018
The system can't perform the operation now. Try again later.
Articles 1–20