Optimal “image‐based” weighting for energy‐resolved CT TG Schmidt Medical physics 36 (7), 3018-3027, 2009 | 190 | 2009 |
An algorithm for constrained one-step inversion of spectral CT data RF Barber, EY Sidky, TG Schmidt, X Pan Physics in Medicine & Biology 61 (10), 3784, 2016 | 98 | 2016 |
An inverse‐geometry volumetric CT system with a large‐area scanned source: A feasibility study TG Schmidt, R Fahrig, NJ Pelc, EG Solomon Medical physics 31 (9), 2623-2627, 2004 | 90 | 2004 |
A prototype table‐top inverse‐geometry volumetric CT system TG Schmidt, J Star‐Lack, NR Bennett, SR Mazin, EG Solomon, R Fahrig, ... Medical physics 33 (6Part1), 1867-1878, 2006 | 67 | 2006 |
CT energy weighting in the presence of scatter and limited energy resolution TG Schmidt Medical physics 37 (3), 1056-1067, 2010 | 60 | 2010 |
Experimental comparison of empirical material decomposition methods for spectral CT KC Zimmerman, TG Schmidt Physics in Medicine & Biology 60 (8), 3175, 2015 | 43 | 2015 |
Sampling in volumetric computed tomography NJ Pelc, TG Schmidt US Patent 7,103,138, 2006 | 36 | 2006 |
A spectral CT method to directly estimate basis material maps from experimental photon-counting data TG Schmidt, RF Barber, EY Sidky IEEE transactions on medical imaging 36 (9), 1808-1819, 2017 | 34 | 2017 |
Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model PA Wolf, JS Jørgensen, TG Schmidt, EY Sidky Physics in Medicine & Biology 58 (16), 5629, 2013 | 26 | 2013 |
Quantifying the tibiofemoral joint space using x‐ray tomosynthesis B Kalinosky, JM Sabol, K Piacsek, B Heckel, T Gilat Schmidt Medical physics 38 (12), 6672-6682, 2011 | 26 | 2011 |
Simulated scatter performance of an inverse‐geometry dedicated breast CT system R Bhagtani, TG Schmidt Medical physics 36 (3), 788-796, 2009 | 24 | 2009 |
A three‐dimensional reconstruction algorithm for an inverse‐geometry volumetric CT system TG Schmidt, R Fahrig, NJ Pelc Medical physics 32 (11), 3234-3245, 2005 | 24 | 2005 |
Region‐of‐interest material decomposition from truncated energy‐resolved CT TG Schmidt, F Pektas Medical physics 38 (10), 5657-5666, 2011 | 21 | 2011 |
Automated selection of the optimal cardiac phase for single‐beat coronary CT angiography reconstruction D Stassi, S Dutta, H Ma, A Soderman, D Pazzani, E Gros, D Okerlund, ... Medical physics 43 (1), 324-335, 2016 | 18 | 2016 |
Phantom study to evaluate the dose and image quality effects of a computed tomography organ‐based tube current modulation technique D Gandhi, DJ Crotty, GM Stevens, TG Schmidt Medical physics 42 (11), 6572-6578, 2015 | 17 | 2015 |
The effects of extending the spectral information acquired by a photon-counting detector for spectral CT TG Schmidt, KC Zimmerman, EY Sidky Physics in Medicine & Biology 60 (4), 1583, 2015 | 16 | 2015 |
An empirical method for correcting the detector spectral response in energy-resolved CT TG Schmidt Medical Imaging 2012: Physics of Medical Imaging 8313, 831312, 2012 | 14 | 2012 |
Biplane fluoroscopy for hindfoot motion analysis during gait: A model-based evaluation JA Cross, BD McHenry, R Molthen, E Exten, TG Schmidt, GF Harris Medical engineering & physics 43, 118-123, 2017 | 12 | 2017 |
Experimental study of optimal energy weighting in energy-resolved CT using a CZT detector F Rupcich, T Gilat-Schmidt Medical Imaging 2013: Physics of Medical Imaging 8668, 86681X, 2013 | 12 | 2013 |
Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and … F Rupcich, A Badal, LM Popescu, I Kyprianou, T Gilat Schmidt Medical physics 40 (8), 081921, 2013 | 11 | 2013 |