Taeyong Lee
Taeyong Lee
Division of Mechanical and Biomedical Engineering, Ewha Womans University
Verified email at ewha.ac.kr
TitleCited byYear
Extreme damping in composite materials with negative-stiffness inclusions
RS Lakes, T Lee, A Bersie, YC Wang
Nature 410 (6828), 565, 2001
4132001
Viscoelastic dissipation in compact bone: implications for stress-induced fluid flow in bone
E Garner, R Lakes, T Lee, C Swan, R Brand
Journal of biomechanical engineering 122, 166, 2000
1182000
Effects of internal stress concentrations in plantar soft-tissue—a preliminary three-dimensional finite element analysis
WM Chen, T Lee, PVS Lee, JW Lee, SJ Lee
Medical engineering & physics 32 (4), 324-331, 2010
1012010
Resonant ultrasound spectroscopy for measurement of mechanical damping: Comparison with broadband viscoelastic spectroscopy
T Lee, RS Lakes, A Lal
Review of Scientific Instruments 71, 2855, 2000
1002000
Anisotropic polyurethane foam with Poisson'sratio greater than 1
T Lee, RS Lakes
Journal of materials science 32 (9), 2397-2401, 1997
731997
Analysis of compressive load on intervertebral joint in standing and sitting postures
M Huang, K Hajizadeh, I Gibson, T Lee
Technology and Health Care 24 (2), 215-223, 2016
602016
Effect of sitting posture on spine joint angles and forces
M Huang, T Lee, I Gibson, K Hajizadeh
Proceedings of the 6th International Conference on Rehabilitation …, 2012
592012
Role of gastrocnemius–soleus muscle in forefoot force transmission at heel rise—A 3D finite element analysis
WM Chen, J Park, SB Park, VPW Shim, T Lee
Journal of biomechanics 45 (10), 1783-1789, 2012
582012
The Influence of Various Seat Design Parameters: A Computational Analysis
M Huang, K Hajizadeh, I Gibson, T Lee
Human Factors and Ergonomics in Manufacturing & Service Industries 26 (3 …, 2016
562016
Predicting failure load of the femur with simulated osteolytic defects using noninvasive imaging technique in a simplified load case
T Lee
Annals of biomedical engineering 35 (4), 642-650, 2007
372007
Re-entrant transformation methods in closed cell foams
R Lakes
Cell Polymers 15, 229-249, 1996
371996
A novel gait platform to measure isolated plantar metatarsal forces during walking
WM Chen, PVS Lee, SB Park, SJ Lee, VPW Shim, T Lee
Journal of biomechanics 43 (10), 2017-2021, 2010
312010
Investigation of bovine bone by resonant ultrasound spectroscopy and transmission ultrasound
T Lee, RS Lakes, A Lal
Biomechanics and modeling in mechanobiology 1 (2), 165-175, 2002
302002
Ibandronate does not reduce the anabolic effects of PTH in ovariectomized rat tibiae: a microarchitectural and mechanical study
X Yang, YH Chan, P Muthukumaran, S DasDe, SH Teoh, T Lee
Bone 48 (5), 1154-1163, 2011
292011
An instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle
WM Chen, VPW Shim, SB Park, T Lee
Journal of biomechanics 44 (9), 1801-1804, 2011
282011
Improving stability of locking compression plates through a design modification: a computational investigation
D Anitha, S Das De, KK Sun, HK Doshi, T Lee
Computer methods in biomechanics and biomedical engineering 18 (2), 153-161, 2015
202015
Positive alterations of viscoelastic and geometric properties in ovariectomized rat femurs with concurrent administration of ibandronate and PTH
X Yang, P Muthukumaran, S DasDe, SH Teoh, H Choi, SK Lim, T Lee
Bone 52 (1), 308-317, 2013
202013
Assessing the susceptibility to local buckling at the femoral neck cortex to age-related bone loss
T Lee, JB Choi, BW Schafer, WP Segars, F Eckstein, V Kuhn, TJ Beck
Annals of biomedical engineering 37 (9), 1910-1920, 2009
202009
Estradiol influences the mechanical properties of human fetal osteoblasts through cytoskeletal changes
P Muthukumaran, CT Lim, T Lee
Biochemical and biophysical research communications 423 (3), 503-508, 2012
172012
Limited forearm motion compensated by thoracohumeral kinematics when performing tasks requiring pronation and supination
BP Pereira, A Thambyah, T Lee
Journal of applied biomechanics 28 (2), 127-138, 2012
142012
The system can't perform the operation now. Try again later.
Articles 1–20