Follow
Joel Poder
Joel Poder
St George Hospital Cancer Care Centre, University of Wollongong
Verified email at uow.edu.au
Title
Cited by
Cited by
Year
Development of a dedicated phantom for multi‐target single‐isocentre stereotactic radiosurgery end to end testing
J Poder, R Brown, H Porter, R Gupta, A Ralston
Journal of applied clinical medical physics 19 (6), 99-108, 2018
272018
I‐125 ROPES eye plaque dosimetry: Validation of a commercial 3D ophthalmic brachytherapy treatment planning system and independent dose calculation software with GafChromic …
J Poder, S Corde
Medical Physics 40 (12), 121709, 2013
262013
An international survey on the clinical use of rigid and deformable image registration in radiotherapy
J Yuen, J Barber, A Ralston, A Gray, A Walker, N Hardcastle, L Schmidt, ...
Journal of Applied Clinical Medical Physics 21 (10), 10-24, 2020
222020
Derivation of in vivo source tracking error thresholds for TRUS-based HDR prostate brachytherapy through simulation of source positioning errors
J Poder, M Carrara, A Howie, D Cutajar, J Bucci, A Rosenfeld
Brachytherapy 18 (5), 711-719, 2019
222019
HDR brachytherapy in vivo source position verification using a 2D diode array: A Monte Carlo study
J Poder, D Cutajar, S Guatelli, M Petasecca, A Howie, J Bucci, ...
Journal of applied clinical medical physics 19 (4), 163-172, 2018
212018
Deforming to best practice: key considerations for deformable image registration in radiotherapy
J Barber, J Yuen, M Jameson, L Schmidt, J Sykes, A Gray, N Hardcastle, ...
Journal of Medical Radiation Sciences 67 (4), 318-332, 2020
202020
A risk-based approach to development of ultrasound-based high-dose-rate prostate brachytherapy quality management
J Poder, R Brown, A Howie, J Yuen, A Ralston, K Schreiber, A Bece, ...
Brachytherapy 17 (5), 788-793, 2018
192018
Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements
J Poder, M Whitaker
Journal of Contemporary Brachytherapy 8 (3), 2016
142016
A Monte Carlo study on the feasibility of real-time in vivo source tracking during ultrasound based HDR prostate brachytherapy treatments
J Poder, D Cutajar, S Guatelli, M Petasecca, A Howie, J Bucci, M Carrara, ...
Physica Medica 59, 30-36, 2019
122019
HDR prostate brachytherapy plan robustness and its effect on in‐vivo source tracking error thresholds: a multi‐institutional study
J Poder, D Koprivec, Y Dookie, A Howie, D Cutajar, AL Damato, N Côté, ...
Medical Physics 49 (6), 3529-3537, 2022
102022
Towards real time in-vivo rectal dosimetry during trans-rectal ultrasound based high dose rate prostate brachytherapy using MOSkin dosimeters
J Poder, A Howie, R Brown, J Bucci, A Rosenfeld, K Enari, K Schreiber, ...
Radiotherapy and Oncology 151, 273-279, 2020
92020
An innovative gynecological HDR brachytherapy applicator system for treatment delivery and real-time verification
A Romanyukha, M Carrara, D Mazzeo, C Tenconi, T Al-Salmani, J Poder, ...
Physica Medica 59, 151-157, 2019
82019
Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
LMM Pudsey, G Biasi, A Ralston, A Rosenfeld, J Poder
Journal of Applied Clinical Medical Physics 23 (9), e13665, 2022
72022
Extrapolated skin dose assessment with optically stimulated luminescent dosimeters
RH Martin Butson, Tom Chen, Samara Alzaidi, Dane Pope, Ethan Butson, Tina ...
Biomedical Physics & Engineering Express 2 (4), 2016
72016
ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system
J Poder, N Annabell, M Geso, M Alqathami, S Corde
Journal of Physics: Conference Series 444 (1), 012102, 2013
72013
The use of collimator angle optimization and jaw tracking for VMAT‐based single‐isocenter multiple‐target stereotactic radiosurgery for up to six targets in the Varian Eclipse …
LMM Pudsey, D Cutajar, A Wallace, A Saba, L Schmidt, A Bece, C Clark, ...
Journal of Applied Clinical Medical Physics 22 (9), 171-182, 2021
62021
Current status of intra-cranial stereotactic radiotherapy and stereotactic radiosurgery in Australia and New Zealand: key considerations from a workshop and surveys
L Pudsey, A Haworth, P White, Z Moutrie, B Jonker, M Foote, J Poder
Physical and Engineering Sciences in Medicine 45 (1), 251-259, 2022
52022
Dose accumulation of multiple high dose rate prostate brachytherapy treatments in two commercially available image registration systems
J Poder, J Yuen, A Howie, A Bece, J Bucci
Physica Medica 43, 43-48, 2017
42017
Feasibility of online adaptive HDR prostate brachytherapy: A novel treatment concept
D Koprivec, A Rosenfeld, D Cutajar, M Petasecca, A Howie, J Bucci, ...
Brachytherapy 21 (6), 943-955, 2022
32022
Use of deformable image registration techniques to estimate dose to organs at risk following prostate external beam radiation therapy and high-dose-rate brachytherapy
M Vozzo, J Poder, J Yuen, J Bucci, A Haworth
Journal of Contemporary Brachytherapy 13 (1), 72-79, 2021
32021
The system can't perform the operation now. Try again later.