Measurement of radiotherapy x‐ray skin dose on a chest wall phantom KY Quach, J Morales, MJ Butson, AB Rosenfeld, PE Metcalfe Medical physics 27 (7), 1676-1680, 2000 | 160 | 2000 |
Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method MJ Butson, R Elferink, T Cheung, KN Peter, M Stokes, KY Quach, ... Physics in Medicine & Biology 45 (11), N143, 2000 | 56 | 2000 |
Matchline dosimetry in step and shoot IMRT fields: a film study P Tangboonduangjit, P Metcalfe, M Butson, KY Quach, A Rosenfeld Physics in Medicine & Biology 49 (17), N287, 2004 | 22 | 2004 |
Dosimetry of blood irradiation with radiochromic film Butson, Cheung, Carolan, Quach, Arnold, Metcalfe Transfusion Medicine 9 (3), 205-208, 1999 | 20 | 1999 |
The role of post-implant dosimetry in the quality assessment of prostate implants. The RAH experience L Marcu, K Quach Australasian Physics & Engineering Sciences in Medicine 29, 310-314, 2006 | 16 | 2006 |
Verification of CT number to density conversion for a simulator-CT attachment A Chapman, M Butson, K Quach, A Rozenfeld, P Metcalfe Australasian Physics & Engineering Sciences in Medicine 25, 78-80, 2002 | 4 | 2002 |
Comparison of effective source-surface distances for electron beams derived from measurements made under different scatter conditions. KY Quach, MJ Butson, PE Metcalfe Australasian Physical & Engineering Sciences in Medicine 22 (3), 99-102, 1999 | 4 | 1999 |
Comparison of three simple radiosurgery techniques for treating elongated lesions DE Zavgorodni, S.F., Quach, K.Y., Roos Physica Medica 15 (2), 57-62, 1999 | 3* | 1999 |
Radiotherapy X-ray dose and tumour control beyond air cavities P Metcalfe, M Butson, K Quach, G Bengua, P Hoban Proceedings of the 22nd Annual International Conference of the IEEE …, 2000 | 1 | 2000 |
Total skin electron therapy: the pitfalls, the peril and the ozone! MD , S. Penfold, K. Quach, T. Rutten Australasian Physical & Engineering Sciences in Medicine 2018 42 (1), 334-335, 2019 | | 2019 |
Evaluation of air-tissue interface dose for a cylindrical air-cavity and anthropomorphic phantom AMCS , Kim Y Quach, Peter E Metcalfe, Anatoly Rosenfeld Australasian Physical & Engineering Sciences in Medicine 2010 34 (1), 161, 2011 | | 2011 |
SIMULATION OF ABSORBED DOSE IN AN EPID USING A MONTE CARLO METHOD TM Pham, E Bezak, K Quach Australasian Physical & Engineering Sciences in Medicine 31 (1), 66, 2008 | | 2008 |
Commissioning RadCalc for Electron Beams G Liu, E Bezak, kim Quach, S Sjostedt Engineering and the Physical Sciences in Medicine (EPSM-abec’2008), 2008 | | 2008 |
Partial Breast Irradiation Using Mammosite Brachytherapy-Clinical Experience K Quach, R Nelligan, M Borg, E Bezak Australasian Physical & Engineering Sciences in Medicine 30 (4), 379, 2007 | | 2007 |
Simulation of Absorbed Dose in an EPID Using a Monte Carlo Method TM Pham, L Fog, K Quach Australasian Physical & Engineering Sciences in Medicine 29 (4), 361-362, 2006 | | 2006 |
Systemic Lupus Erythematosis and Prostate Seed Brachytherapy E Yeoh, J Aspinall, K Quach The 15 th Australasian Brachytherapy Group Annual Scientific Meeting, 2006 | | 2006 |
Is Post-Implant Dosimetry a Reliable Check Tool for the Quality of Prostate Implants? L Marcu, k Quach, E Yeoh, R Gowda, D Steele, M Borg, S Chryssidis The 15 th Australasian Brachytherapy Group Annual Scientific Meeting, 2006 | | 2006 |
Simulation of the Absorbed Dose in an EPID Using the Monte Carlo Method T Pham, L Fog, K Quach Australasian Physical & Engineering Sciences in Medicine 28 (4), 277-278, 2005 | | 2005 |
Post-implant Dosimetry for I-125 Prostate Implants: Multi-observer Intercomparison L Marcu, K Quach Australasian Physical & Engineering Sciences in Medicine 28 (4), 273, 2005 | | 2005 |
Intensity-Modulated Radiation Therapy (IMRT) Dose Verification: Measuring The Match Line Effect P Tangboonduangjit, P Metcalfe, M Butson, KY Quach, A Rosenfeld World Congress on Medical Physics and Biomedical Engineering, 2003 | | 2003 |