Follow
Manuela Teresa Raimondi
Manuela Teresa Raimondi
Verified email at polimi.it - Homepage
Title
Cited by
Cited by
Year
Controlling self-renewal and differentiation of stem cells via mechanical cues
MM Nava, MT Raimondi, R Pietrabissa
BioMed Research International 2012, 2012
2642012
The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating
MT Raimondi, R Pietrabissa
Biomaterials 21 (9), 907-913, 2000
2602000
Modeling evaluation of the fluid‐dynamic microenvironment in tissue‐engineered constructs: A micro‐CT based model
M Cioffi, F Boschetti, MT Raimondi, G Dubini
Biotechnology and bioengineering 93 (3), 500-510, 2006
2222006
Prediction of the micro-fluid dynamic environment imposed to three-dimensional engineered cell systems in bioreactors
F Boschetti, MT Raimondi, F Migliavacca, G Dubini
Journal of biomechanics 39 (3), 418-425, 2006
2082006
Two-photon laser polymerization: from fundamentals to biomedical application in tissue engineering and regenerative medicine
MT Raimondi, SM Eaton, MM Nava, M Laganą, G Cerullo, R Osellame
Journal of applied biomaterials & functional materials 10 (1), 56-66, 2012
2062012
A 3D microfluidic model for preclinical evaluation of TCR-engineered T cells against solid tumors
A Pavesi, AT Tan, S Koh, A Chia, M Colombo, E Antonecchia, C Miccolis, ...
JCI insight 2 (12), 2017
1902017
Natural and synthetic polymers for bone scaffolds optimization
F Donnaloja, E Jacchetti, M Soncini, MT Raimondi
Polymers 12 (4), 905, 2020
1872020
Human bone perivascular niche-on-a-chip for studying metastatic colonization
A Marturano-Kruik, MM Nava, K Yeager, A Chramiec, L Hao, S Robinson, ...
Proceedings of the National Academy of Sciences 115 (6), 1256-1261, 2018
1862018
Mechanobiology of engineered cartilage cultured under a quantified fluid-dynamic environment
MT Raimondi, F Boschetti, L Falcone, GB Fiore, A Remuzzi, E Marinoni, ...
Biomechanics and modeling in mechanobiology 1, 69-82, 2002
1682002
Three-dimensional structural niches engineered via two-photon laser polymerization promote stem cell homing
MT Raimondi, SM Eaton, M Laganą, V Aprile, MM Nava, G Cerullo, ...
Acta biomaterialia 9 (1), 4579-4584, 2013
1672013
Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentuous mandible: a biomechanical study.
CM Bellini, D Romeo, F Galbusera, S Taschieri, MT Raimondi, A Zampelis, ...
International Journal of Oral & Maxillofacial Implants 24 (3), 2009
1652009
Elastic stabilization alone or combined with rigid fusion in spinal surgery: a biomechanical study and clinical experience based on 82 cases
S Caserta, G La Maida, B Misaggi, D Peroni, R Pietrabissa, M Raimondi, ...
European Spine Journal 11, S192-S197, 2002
1522002
Elastic stabilization alone or combined with rigid fusion in spinal surgery: a biomechanical study and clinical experience based on 82 cases
S Caserta, G La Maida, B Misaggi, D Peroni, R Pietrabissa, M Raimondi, ...
European Spine Journal 11, S192-S197, 2002
1522002
A double-chamber rotating bioreactor for the development of tissue-engineered hollow organs: from concept to clinical trial
MA Asnaghi, P Jungebluth, MT Raimondi, SC Dickinson, LEN Rees, T Go, ...
Biomaterials 30 (29), 5260-5269, 2009
1472009
The effect of hydrodynamic shear on 3D engineered chondrocyte systems subject to direct perfusion
MT Raimondi, M Moretti, M Cioffi, C Giordano, F Boschetti, K Lagana, ...
Biorheology 43 (3-4), 215-222, 2006
1292006
Cervical spine biomechanics following implantation of a disc prosthesis
F Galbusera, CM Bellini, MT Raimondi, M Fornari, R Assietti
Medical engineering & physics 30 (9), 1127-1133, 2008
1182008
The effect of media perfusion on three‐dimensional cultures of human chondrocytes: Integration of experimental and computational approaches
MT Raimondi, F Boschetti, L Falcone, F Migliavacca, A Remuzzi, G Dubini
Biorheology 41 (3-4), 401-410, 2004
1182004
Biomechanics of the lumbar spine after dynamic stabilization
CM Bellini, F Galbusera, MT Raimondi, GV Mineo, M Brayda-Bruno
Clinical Spine Surgery 20 (6), 423-429, 2007
1112007
Biomechanics of the C5-C6 spinal unit before and after placement of a disc prosthesis
F Galbusera, A Fantigrossi, MT Raimondi, R Assietti, M Sassi, M Fornari
Biomechanics and modeling in mechanobiology 5 (4), 253-261, 2006
1022006
Design concepts in lumbar total disc arthroplasty
F Galbusera, CM Bellini, T Zweig, S Ferguson, MT Raimondi, C Lamartina, ...
European spine journal 17, 1635-1650, 2008
982008
The system can't perform the operation now. Try again later.
Articles 1–20