Follow
Lars Gunnarsen
Lars Gunnarsen
Department of the built environment (Build), Aalborg University
Verified email at build.aau.dk
Title
Cited by
Cited by
Year
Indoor particles affect vascular function in the aged: an air filtration–based intervention study
EV Brauner, L Forchhammer, P Møller, L Barregard, L Gunnarsen, ...
American journal of respiratory and critical care medicine 177 (4), 419-425, 2008
3082008
Emission of di-2-ethylhexyl phthalate from PVC flooring into air and uptake in dust: emission and sorption experiments in FLEC and CLIMPAQ
PA Clausen, V Hansen, L Gunnarsen, A Afshari, P Wolkoff
Environmental science & technology 38 (9), 2531-2537, 2004
2742004
Emission of phthalates from PVC and other materials.
A Afshari, L Gunnarsen, PA Clausen, V Hansen
Indoor air 14 (2), 2004
2442004
Adaptation to indoor air pollution
L Gunnarsen, PO Fanger
Environment International 18 (1), 43-54, 1992
2081992
Diffusion and sorption of volatile organic compounds in building materials− Impact on indoor air quality
R Meininghaus, L Gunnarsen, HN Knudsen
Environmental Science & Technology 34 (15), 3101-3108, 2000
1892000
Achieving the desired indoor climate: energy efficiency aspects of system design
PE Nilsson, E Abel, L Ekberg, P Fahlén, R Clark, PO Fanger, C Fitzner, ...
Studentlitteratur, 2003
1442003
An indoor air filtration study in homes of elderly: cardiovascular and respiratory effects of exposure to particulate matter
DG Karottki, M Spilak, M Frederiksen, L Gunnarsen, EV Brauner, B Kolarik, ...
Environmental Health 12, 1-10, 2013
1392013
Design and characterization of the CLIMPAQ, chamber for laboratory investigations of materials, pollution and air quality
L Gunnarsen, PA Nielsen, P Wolkoff
Indoor Air 4 (1), 56-62, 1994
1051994
Indoor and outdoor exposure to ultrafine, fine and microbiologically derived particulate matter related to cardiovascular and respiratory effects in a panel of elderly urban …
DG Karottki, M Spilak, M Frederiksen, ZJ Andersen, AM Madsen, M Ketzel, ...
International journal of environmental research and public health 12 (2 …, 2015
912015
Polychlorinated biphenyls (PCBs) in indoor air originating from sealants in contaminated and uncontaminated apartments within the same housing estate
M Frederiksen, HW Meyer, NE Ebbehøj, L Gunnarsen
Chemosphere 89 (4), 473-479, 2012
912012
Emission of isothiazolinones from water-based paints
MD Lundov, B Kolarik, R Bossi, L Gunnarsen, JD Johansen
Environmental science & technology 48 (12), 6989-6994, 2014
882014
Evaluation of building characteristics in 27 dwellings in Denmark and the effect of using particle filtration units on PM2. 5 concentrations
MP Spilak, GD Karottki, B Kolarik, M Frederiksen, S Loft, L Gunnarsen
Building and Environment 73, 55-63, 2014
78*2014
Sampling, extraction and measurement of bacteria, endotoxin, fungi and inflammatory potential of settling indoor dust
AM Madsen, CB Matthiesen, MW Frederiksen, M Frederiksen, M Frankel, ...
Journal of environmental monitoring 14 (12), 3230-3239, 2012
722012
Diurnal and seasonal variation in air exchange rates and interzonal airflows measured by active and passive tracer gas in homes
G Bekö, S Gustavsen, M Frederiksen, NC Bergsøe, B Kolarik, ...
Building and Environment 104, 178-187, 2016
672016
Plasma polychlorinated biphenyls in residents of 91 PCB-contaminated and 108 non-contaminated dwellings—an exposure study
HW Meyer, M Frederiksen, T Göen, NE Ebbehøj, L Gunnarsen, C Brauer, ...
International journal of hygiene and environmental health 216 (6), 755-762, 2013
632013
Prediction of indoor concentration of 0.5–4 μm particles of outdoor origin in an uninhabited apartment
T Schneider, KA Jensen, PA Clausen, A Afshari, L Gunnarsen, P Wåhlin, ...
Atmospheric Environment 38 (37), 6349-6359, 2004
542004
Documentation Of Field And Laboratory Emission Cell “FLEC”: Identification Of Emission Processes From Carpet, Linoleum, Paint, And Sealant By Modeling⋆
P Wolkoff, PA Clausen, PA Nielsen, L Gunnarsen
Indoor Air 3 (4), 291-297, 1993
471993
Partitioning of PCB s from air to clothing materials in a Danish apartment
GC Morrison, HV Andersen, L Gunnarsen, D Varol, E Uhde, B Kolarik
Indoor Air 28 (1), 188-197, 2018
442018
Impact of dwelling characteristics on concentrations of bacteria, fungi, endotoxin and total inflammatory potential in settled dust
MP Spilak, AM Madsen, SM Knudsen, B Kolarik, EW Hansen, ...
Building and Environment 93, 64-71, 2015
442015
PCB in air, dust and surface wipes in 73 Danish homes
HV Andersen, L Gunnarsen, LE Knudsen, M Frederiksen
International Journal of Hygiene and Environmental Health 229, 113429, 2020
412020
The system can't perform the operation now. Try again later.
Articles 1–20