Follow
Simon Goodall
Simon Goodall
University of Western Australia, GenesisCare
Verified email at genesiscare.com
Title
Cited by
Cited by
Year
Clinical implementation of photon beam flatness measurements to verify beam quality
S Goodall, N Harding, J Simpson, L Alexander, S Morgan
Journal of Applied Clinical Medical Physics 16 (6), 340-345, 2015
212015
Investigation of the effects of spinal surgical implants on radiotherapy dosimetry: A study of 3D printed phantoms
SK Goodall, P Rampant, W Smith, D Waterhouse, P Rowshanfarzad, ...
Medical Physics 48 (8), 4586-4597, 2021
142021
Recommended dose voxel size and statistical uncertainty parameters for precision of Monte Carlo dose calculation in stereotactic radiotherapy
SK Goodall, MA Ebert
Journal of Applied Clinical Medical Physics 21 (12), 120-130, 2020
122020
Investigation of Elekta AQUA software for kilovoltage to megavoltage radiation isocenter coincidence
C Norvill, F Bockelmann, P Blumenberg, S Goodall
Physical and Engineering Sciences in Medicine 44 (3), 667-675, 2021
42021
Investigation of pixel scale calibration on the Elekta iView electronic portal imager
C Norvill, S Goodall
Journal of Applied Clinical Medical Physics 22 (8), 148-155, 2021
42021
Matched linac stereotactic radiotherapy: An assessment of delivery similarity and distributive patient‐specific quality assurance feasibility
SK Goodall, L Dunn, J Dunning, L Muñoz, P Rowshanfarzad, MA Ebert
Journal of Applied Clinical Medical Physics 23 (11), e13652, 2022
22022
Comprehensive investigation into the stability of Varian and Elekta kV imaging systems during arc delivery
B Wright, GM Hassan, G Mukwada, M Ebert, S Goodall, M Sabet, ...
Biomedical Physics & Engineering Express 6 (6), 065017, 2020
22020
Accuracy of the catalyst surface guidance system for patient monitoring during cranial SRS treatments
K Tonkin, SK Goodall
Physical and Engineering Sciences in Medicine 46 (2), 633-643, 2023
12023
Deriving optimal planning organ at risk volume margins in prostate external beam radiotherapy
Y Zhao, MA Ebert, D Waterhouse, S Goodall, P Rowshanfarzad, S Fattahi
Physical and Engineering Sciences in Medicine 44 (4), 1071-1080, 2021
12021
A method for improving the calibration reproducibility of an ionization chamber detector array
S Goodall, S Morgan
Medical Physics 41 (9), 091704, 2014
12014
Peripheral doses outside the electron applicators in an Elekta Versa HD Linac
KD Maharaj, S Goodall, M Sabet, J Dass, M Ibrahim, T Mahmood, ...
2024
Initial end-to-end testing of the ExacTrac dynamic deep inspiration breath hold workflow using a breath hold breast phantom
SK Goodall, PL Rampant
Physical and Engineering Sciences in Medicine 46 (3), 1239-1247, 2023
2023
Correction factors for commissioning and patient specific quality assurance of stereotactic fields in a Monte Carlo based treatment planning system: TPS correction factors
SK Goodall, P Rowshanfarzad, MA Ebert
Physical and Engineering Sciences in Medicine 46 (2), 735-745, 2023
2023
PO-1590 Treatment planning of spine and pelvis using SEMAR-corrected CT sets
D Ignatius, M Sabet, P Rowshanfarzad, Z Alkhatib, S Goodall, M Ibrahim, ...
Radiotherapy and Oncology 182, S1291, 2023
2023
Radiotherapy planning of spine and pelvis using single-energy metal artifact reduction corrected computed tomography sets
D Ignatius, Z Alkhatib, P Rowshanfarzad, S Goodall, M Ibrahim, A Hirst, ...
Physics and Imaging in Radiation Oncology 26, 100449, 2023
2023
Variation in Elekta iView electronic portal imager pixel scale factor with gantry angle, and impact on multi‐leaf collimator quality assurance
SK Goodall, C Norvill
Journal of Applied Clinical Medical Physics 23 (7), e13661, 2022
2022
The system can't perform the operation now. Try again later.
Articles 1–16