Follow
Alireza Mortezaei
Alireza Mortezaei
Associate Professor in Structural Earthquake Engineering, Semnan branch, Islamic Azad University
Verified email at semnaniau.ac.ir
Title
Cited by
Cited by
Year
Seismic evaluation of FRP strengthened RC buildings subjected to near-fault ground motions having fling step
A Mortezaei, HR Ronagh, A Kheyroddin
Composite Structures 92 (5), 1200-1211, 2010
692010
Plastic hinge length of FRP strengthened reinforced concrete columns subjected to both far-fault and near-fault ground motions
A Mortezaei, HR Ronagh
Scientia Iranica 19 (6), 1365-1378, 2012
572012
Plastic hinge length of reinforced concrete columns subjected to both far‐fault and near‐fault ground motions having forward directivity
A Mortezaei, HR Ronagh
The Structural Design of Tall and Special Buildings 22 (12), 903-926, 2013
512013
Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near‐fault earthquakes having forward directivity
A Mortezaei, HR Ronagh, A Kheyroddin, GG Amiri
The structural design of tall and special buildings 20 (6), 679-699, 2011
362011
Finite element analysis and seismic rehabilitation of a 1000‐year‐old heritage listed tall masonry mosque
A Mortezaei, A Kheyroddin, HR Ronagh
The Structural Design of Tall and Special Buildings 21 (5), 334-353, 2012
282012
The effect of element size and plastic hinge characteristics on nonlinear analysis of RC frames
A Kheyroddin, A Mortezaei
Iranian Journal of Science & Technology, Transaction B, Engineering 32 (B5 …, 2008
282008
Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step
A Mortezaei, HR Ronagh
Natural Hazards and Earth System Science 13 (6), 1579-1593, 2013
262013
A new energy-absorbing system for seismic retrofitting of frame structures with slender braces
V Mohsenian, A Mortezaei
Bulletin of Earthquake Engineering 17 (5), 2715-2739, 2019
242019
Plastic hinge length of RC columns under the combined effect of near-fault vertical and horizontal ground motions
A Mortezaei
Periodica Polytechnica Civil Engineering 58 (3), 243-253, 2014
222014
Influence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
RC Barros, H Naderpour, SM Khatami, A Mortezaei
Journal of Rehabilitation in Civil Engineering 1 (1), 39-52, 2013
222013
Comparing effects of openings in concrete shear walls under near-fault ground motions
SM Khatami, A Mortezaei, RC Barros
Proceedings of 15th World Conference on Earthquake Engineering, Lisbon, Portugal, 2012
222012
Plastic hinge length of RC columns considering soil-structure interaction
A Mortezaei
Earthquakes and Structures 5 (6), 679-702, 2013
192013
Evaluation of seismic reliability and multi level response reduction factor (R factor) for eccentric braced frames with vertical links
V Mohsenian, A Mortezaei
Earthquakes and Structures 14 (6), 537-549, 2018
182018
Seismic reliability evaluation of tunnel form (box‐type) RC structures under the accidental torsion
V Mohsenian, A Mortezaei
Structural Concrete, 2018
152018
Seismic Assessment of the World’s Tallest Pure-Brick Tower Including Soil-Structure Interaction
A Mortezaei, A Motaghi
Journal of Performance of Constructed Facilities, 04016020, 2016
152016
Seismic Performance of High-Rise RC Shear Wall Buildings Subjected to Ground Motions with Various Frequency Contents
A Afzali, A Mortezaei, A Kheyroddin
Civil Engineering Journal 3 (8), 568-584, 2017
142017
Effect of steel coupling beam on the seismic reliability and R-factor of box-type buildings
V Mohsenian, A Mortezaei
Proceedings of the Institution of Civil Engineers-Structures and Buildings …, 2019
132019
A new expression for determining the bending stiffness of circular micropile groups
K Abdollahi, A Mortezaei
Soil Dynamics and Earthquake Engineering 77, 58-70, 2015
132015
Seismic response of reinforced concrete building with viscoelastic damper under near field earthquake
A Mortezaei, SM Zahrai
Asian Journal of Civil Engineering (Building and Housing) 9 (3), 347-359, 2009
122009
Reliability-based seismic assessment of multi-story box system buildings under the accidental torsion
A Mortezaei, V Mohsenian
Journal of Earthquake Engineering 26 (2), 674-697, 2022
112022
The system can't perform the operation now. Try again later.