Semiconductor real-time quality assurance dosimetry in brachytherapy M Carrara, D Cutajar, S Alnaghy, A Espinoza, A Romanyukha, S Presilla, ... Brachytherapy 17 (1), 133-145, 2018 | 17 | 2018 |
BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom S Alnaghy, DL Cutajar, JA Bucci, K Enari, M Safavi-Naeini, M Favoino, ... Physica Medica 34, 55-64, 2017 | 16 | 2017 |
Polymer Photodetectors for Printable, Flexible, and Fully Tissue Equivalent X‐Ray Detection with Zero‐Bias Operation and Ultrafast Temporal Responses JA Posar, J Davis, S Alnaghy, D Wilkinson, S Cottam, DM Lee, ... Advanced Materials Technologies 6 (9), 2001298, 2021 | 15 | 2021 |
Flexible polymer X-ray detectors with non-fullerene acceptors for enhanced stability: Toward printable tissue equivalent devices for medical applications MJ Large, JA Posar, AJ Mozer, A Nattestad, S Alnaghy, M Carolan, ... ACS applied materials & interfaces 13 (48), 57703-57712, 2021 | 13 | 2021 |
Medipix detectors in radiation therapy for advanced quality-assurance A Rosenfeld, S Alnaghy, M Petasecca, D Cutajar, M Lerch, S Pospisil, ... Radiation Measurements 130, 106211, 2020 | 13 | 2020 |
Analytical modelling and simulation of single and double cone pinholes for real-time in-body tracking of an HDR brachytherapy source S Alnaghy, M Safavi-Naeini, DR Franklin, Z Han, DL Cutajar, M Petasecca, ... IEEE Transactions on Nuclear Science 63 (3), 1375-1385, 2016 | 13 | 2016 |
A six-degree-of-freedom robotic motion system for quality assurance of real-time image-guided radiotherapy S Alnaghy, A Kyme, V Caillet, DT Nguyen, R O’Brien, JT Booth, PJ Keall Physics in Medicine & Biology 64 (10), 105021, 2019 | 12 | 2019 |
Towards high spatial resolution tissue-equivalent dosimetry for microbeam radiation therapy using organic semiconductors JA Posar, M Large, S Alnaghy, JR Paino, DJ Butler, MJ Griffith, S Hood, ... Journal of synchrotron radiation 28 (5), 1444-1454, 2021 | 9 | 2021 |
On the evaluation of edgeless diode detectors for patient-specific QA in high-dose stereotactic radiosurgery E De Martin, S Alhujaili, ML Fumagalli, F Ghielmetti, M Marchetti, P Gallo, ... Physica Medica 89, 20-28, 2021 | 5 | 2021 |
BrachyView: multiple seed position reconstruction and comparison with CT post-implant dosimetry S Alnaghy, KJ Loo, DL Cutajar, M Jalayer, C Tenconi, M Favoino, R Rietti, ... Journal of Instrumentation 11 (05), P05002, 2016 | 5 | 2016 |
Experimental evaluation of the dosimetric impact of intrafraction prostate rotation using film measurement with a 6DoF robotic arm K Shi, A Dipuglia, J Booth, S Alnaghy, A Kyme, P Keall, DT Nguyen Medical physics 47 (12), 6068-6076, 2020 | 3 | 2020 |
BrachyView: Reconstruction of seed positions and volume of an LDR prostate brachytherapy patient plan using a baseline subtraction algorithm T Brennen, DL Cutajar, S Alnaghy, J Bucci, A Bece, K Enari, M Favoino, ... Physica Medica 66, 66-76, 2019 | 2 | 2019 |
BrachyView: initial preclinical results for a real-time in-body HDR PBT source tracking system with simultaneous TRUS image fusion S Alnaghy, DL Cutajar, M Safavi-Naeini, S George, A Howie, A Bece, ... Physics in Medicine & Biology 64 (8), 085002, 2019 | 2 | 2019 |
BrachyView: verification of LDR patient plans–hardware optimisation T Brennen, DL Cutajar, S Alnaghy, J Bucci, A Bece, M Favoino, ... Journal of Physics: Conference Series 1154 (1), 012005, 2019 | 2 | 2019 |
Introduction and implementation of the CMRP radiodosimeter—a novel wireless microdosimetry system J Vohradsky, L Chartier, A Pogossov, S Alnaghy, J Paino, S Peracchi, ... Journal of Instrumentation 17 (03), P03006, 2022 | 1 | 2022 |
A large area pixelated silicon array detector for independent transit in vivo dosimetry OJ Brace, I Fuduli, S Alnaghy, AT Le, JA Davis, T Causer, D Wilkinson, ... Applied Sciences 12 (2), 537, 2022 | 1 | 2022 |
BrachyView: development of an algorithm for real-time automatic LDR brachytherapy seed detection T Brennen, L Galli, DL Cutajar, S Alnaghy, J Bucci, A Bece, K Enari, ... Physics in Medicine & Biology 65 (21), 215015, 2020 | 1 | 2020 |
A Novel Six-Degrees-Of-Freedom (6DoF) Robotic Motion Phantom Quality-Assurance (QA) to Test Advanced Radiotherapy Delivery Approaches S Alnaghy, A Kyme, V Caillet, D Nguyen, R O'Brien, J Booth, P Keall MEDICAL PHYSICS 45 (6), E682-E682, 2018 | 1 | 2018 |
6-DoF Robotic Motion Phantom: An Open-Source Project for Quality Assurance of Real-Time Image-Guided Radiotherapy Technologies C Sengupta, S Alnaghy, D Nguyen, A Kyme, K Makhija, T Moodie, ... MEDICAL PHYSICS 48 (6), 2021 | | 2021 |
Quality Assurance for the Clinical Implementation of Kilovoltage Intrafraction Monitoring (KIM) in the TROG 17.03 Liver Ablative Radiotherapy with KIM (LARK) Multi … C Sengupta, D Nguyen, T Moodie, S Alnaghy, R O'Brien, PJ Keall MEDICAL PHYSICS 47 (6), E435-E435, 2020 | | 2020 |