Jan Laufer
Jan Laufer
Martin-Luther-Universität Halle-Wittenberg
Verified email at tu-berlin.de
TitleCited byYear
Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues
E Zhang, J Laufer, P Beard
Applied optics 47 (4), 561-577, 2008
4332008
Quantitative spectroscopic photoacoustic imaging: a review
BT Cox, JG Laufer, PC Beard, SR Arridge
Journal of biomedical optics 17 (6), 061202, 2012
3882012
Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and …
J Laufer, D Delpy, C Elwell, P Beard
Physics in Medicine & Biology 52 (1), 141, 2006
3132006
In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
EZ Zhang, JG Laufer, RB Pedley, PC Beard
Physics in Medicine & Biology 54 (4), 1035, 2009
2942009
Effect of temperature on the optical properties of ex vivo human dermis and subdermis
J Laufer, R Simpson, M Kohl, M Essenpreis, M Cope
Physics in Medicine & Biology 43 (9), 2479, 1998
2581998
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
AP Jathoul, J Laufer, O Ogunlade, B Treeby, B Cox, E Zhang, P Johnson, ...
Nature Photonics 9 (4), 239, 2015
2182015
In vivo preclinical photoacoustic imaging of tumor vasculature development and therapy
JG Laufer, EZ Zhang, BE Treeby, BT Cox, PC Beard, P Johnson, B Pedley
Journal of biomedical optics 17 (5), 056016, 2012
2132012
In vitro measurements of absolute blood oxygen saturation using pulsed near-infrared photoacoustic spectroscopy: accuracy and resolution
J Laufer, C Elwell, D Delpy, P Beard
Physics in Medicine & Biology 50 (18), 4409, 2005
1852005
The challenges for quantitative photoacoustic imaging
BT Cox, JG Laufer, PC Beard
Photons Plus Ultrasound: Imaging and Sensing 2009 7177, 717713, 2009
1492009
Multimodal photoacoustic and optical coherence tomography scanner using an all optical detection scheme for 3D morphological skin imaging
EZ Zhang, B Povazay, J Laufer, A Alex, B Hofer, B Pedley, C Glittenberg, ...
Biomedical optics express 2 (8), 2202-2215, 2011
1422011
Three-dimensional noninvasive imaging of the vasculature in the mouse brain using a high resolution photoacoustic scanner
J Laufer, E Zhang, G Raivich, P Beard
Applied optics 48 (10), D299-D306, 2009
1332009
Quantitative determination of chromophore concentrations from 2D photoacoustic images using a nonlinear model-based inversion scheme
J Laufer, B Cox, E Zhang, P Beard
Applied optics 49 (8), 1219-1233, 2010
1152010
A comparison of the strength of knots tied by hand and at laparoscopy.
SS Kadirkamanathan, JC Shelton, CC Hepworth, JG Laufer, CP Swain
Journal of the American College of Surgeons 182 (1), 46-54, 1996
751996
Accuracy and resolution of THz reflection spectroscopy for medical imaging
CB Reid, E Pickwell-MacPherson, JG Laufer, AP Gibson, JC Hebden, ...
Physics in Medicine & Biology 55 (16), 4825, 2010
722010
Automatic sound speed selection in photoacoustic image reconstruction using an autofocus approach
BE Treeby, TK Varslot, EZ Zhang, JG Laufer, PC Beard
Journal of biomedical optics 16 (9), 090501, 2011
622011
In vivo photoacoustic imaging of mouse embryos
J Laufer, FC Norris, JO Cleary, EZ Zhang, BE Treeby, BT Cox, ...
Journal of biomedical optics 17 (6), 061220, 2012
602012
Evaluation of absorbing chromophores used in tissue phantoms for quantitative photoacoustic spectroscopy and imaging
J Laufer, E Zhang, P Beard
IEEE journal of selected topics in quantum electronics 16 (3), 600-607, 2010
572010
In vitro characterization of genetically expressed absorbing proteins using photoacoustic spectroscopy
J Laufer, A Jathoul, M Pule, P Beard
Biomedical optics express 4 (11), 2477-2490, 2013
512013
Three-dimensional photoacoustic imaging of vascular anatomy in small animals using an optical detection system
EZ Zhang, J Laufer, P Beard
Photons Plus Ultrasound: Imaging and Sensing 2007: The Eighth Conference on …, 2007
502007
Re‐evaluation of differential phase contrast (DPC) in a scanning laser microscope using a split detector as an alternative to differential interference contrast (DIC) optics
WB Amos, S Reichelt, DM Cattermole, J Laufer
Journal of microscopy 210 (2), 166-175, 2003
482003
The system can't perform the operation now. Try again later.
Articles 1–20