A direct comparison of wet, dry and insulating bioelectric recording electrodes A Searle, L Kirkup Physiological measurement 21 (2), 271, 2000 | 862 | 2000 |
An introduction to uncertainty in measurement: using the GUM (guide to the expression of uncertainty in measurement) L Kirkup, RB Frenkel Cambridge University Press, 2006 | 514 | 2006 |
Development of an algorithm for an EEG-based driver fatigue countermeasure SKL Lal, A Craig, P Boord, L Kirkup, H Nguyen Journal of safety Research 34 (3), 321-328, 2003 | 477 | 2003 |
Factors affecting internal standard selection for quantitative elemental bio-imaging of soft tissues by LA-ICP-MS C Austin, F Fryer, J Lear, D Bishop, D Hare, T Rawling, L Kirkup, ... Journal of Analytical Atomic Spectrometry 26 (7), 1494-1501, 2011 | 114 | 2011 |
EEG-based system for rapid on-off switching without prior learning L Kirkup, A Searle, A Craig, P McIsaac, P Moses Medical and Biological Engineering and Computing 35, 504-509, 1997 | 108 | 1997 |
The effectiveness of a hands-free environmental control system for the profoundly disabled A Craig, P Moses, Y Tran, P McIsaac, L Kirkup Archives of physical medicine and rehabilitation 83 (10), 1455-1458, 2002 | 68 | 2002 |
Comparison of linear and non-linear equations for univariate calibration L Kirkup, M Mulholland Journal of Chromatography A 1029 (1-2), 1-11, 2004 | 50 | 2004 |
Data analysis with Excel®: an introduction for physical scientists L Kirkup Cambridge University Press, 2002 | 49 | 2002 |
Control of a hand grasp neuroprosthesis using an electroencephalogram-triggered switch: demonstration of improvements in performance using wavepacket analysis JM Heasman, TRD Scott, L Kirkup, RY Flynn, VA Vare, CR Gschwind Medical and Biological Engineering and Computing 40, 588-593, 2002 | 43 | 2002 |
Real time impedance plots with arbitrary frequency components A Searle, L Kirkup Physiological measurement 20 (1), 103, 1999 | 43 | 1999 |
Alpha wave reactivity following eye closure: a potential method of remote hands free control for the disabled A Craig, P McIsaac, Y Tran, L Kirkup, A Searle Technology and Disability 10 (3), 187-194, 1999 | 37 | 1999 |
Measurement uncertainty as a threshold concept in physics A Wilson, G Akerlind, P Francis, L Kirkup, JA McKenzie, D Pearce, ... Uniserve Science Annual Conference, 2010 | 34 | 2010 |
A guide to GUM L Kirkup European journal of physics 23 (5), 483, 2002 | 32 | 2002 |
Three methods compared for detecting the onset of alpha wave synchronization following eye closure L Kirkup, A Searle, A Craig, P McIsaac, G Larsen Physiological measurement 19 (2), 213, 1998 | 30 | 1998 |
Comparison of equations describing band broadening in high-performance liquid chromatography L Kirkup, M Foot, M Mulholland Journal of Chromatography A 1030 (1-2), 25-31, 2004 | 28 | 2004 |
Data analysis with excel L Kirkup Data Analysis with Excel, 464, 2002 | 28 | 2002 |
The effectiveness of activating electrical devices using alpha wave synchronisation contingent with eye closure A Craig, Y Tran, P McIsaac, P Moses, L Kirkup, A Searle Applied ergonomics 31 (4), 377-382, 2000 | 28 | 2000 |
Monte Carlo-based estimation of uncertainty owing to limited resolution of digital instruments RB Frenkel, L Kirkup Metrologia 42 (5), L27, 2005 | 24 | 2005 |
Designing a new physics laboratory programme for first-year engineering students L Kirkup, S Johnson, E Hazel, RW Cheary, DC Green, P Swift, W Holliday Physics education 33 (4), 258, 1998 | 23 | 1998 |
Data analysis for physical scientists: Featuring Excel® L Kirkup Cambridge University Press, 2012 | 21 | 2012 |