Follow
Benjamin Nelms
Benjamin Nelms
Canis Lupus LLC
Verified email at canislupusllc.com - Homepage
Title
Cited by
Cited by
Year
hMre11 and hRad50 nuclear foci are induced during the normal cellular response to DNA double-strand breaks
RS Maser, KJ Monsen, BE Nelms, JHJ Petrini
Molecular and cellular biology, 1997
6671997
In situ visualization of DNA double-strand break repair in human fibroblasts
BE Nelms, RS Maser, JF MacKay, MG Lagally, JHJ Petrini
Science 280 (5363), 590-592, 1998
6241998
Per‐beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors
BE Nelms, H Zhen, WA Tomé
Medical physics 38 (2), 1037-1044, 2011
4902011
Variation in external beam treatment plan quality: an inter-institutional study of planners and planning systems
BE Nelms, G Robinson, J Markham, K Velasco, S Boyd, S Narayan, ...
Practical radiation oncology 2 (4), 296-305, 2012
4342012
Moving from gamma passing rates to patient DVH‐based QA metrics in pretreatment dose QA
H Zhen, BE Nelms, WA Tomé
Medical physics 38 (10), 5477-5489, 2011
3052011
A survey on planar IMRT QA analysis
BE Nelms, JA Simon
Journal of applied clinical medical physics 8 (3), 76-90, 2007
2602007
Variations in the contouring of organs at risk: test case from a patient with oropharyngeal cancer
BE Nelms, WA Tomé, G Robinson, J Wheeler
International Journal of Radiation Oncology* Biology* Physics 82 (1), 368-378, 2012
2532012
Evaluating IMRT and VMAT dose accuracy: practical examples of failure to detect systematic errors when applying a commonly used metric and action levels
BE Nelms, MF Chan, G Jarry, M Lemire, J Lowden, C Hampton, ...
Medical physics 40 (11), 111722, 2013
2402013
Evaluation of a new VMAT QA device, or the “X” and “O” array geometries
V Feygelman, G Zhang, C Stevens, BE Nelms
Journal of applied clinical medical physics 12 (2), 146-168, 2011
1752011
Alteration of N-terminal phosphoesterase signature motifs inactivates Saccharomyces cerevisiae Mre11
DA Bressan, HA Olivares, BE Nelms, JHJ Petrini
Genetics 150 (2), 591-600, 1998
1751998
VMAT QA: measurement‐guided 4D dose reconstruction on a patient
BE Nelms, D Opp, J Robinson, TK Wolf, G Zhang, E Moros, V Feygelman
Medical physics 39 (7Part1), 4228-4238, 2012
1272012
Experimentally studied dynamic dose interplay does not meaningfully affect target dose in VMAT SBRT lung treatments
C Stambaugh, BE Nelms, T Dilling, C Stevens, K Latifi, G Zhang, E Moros, ...
Medical physics 40 (9), 091710, 2013
962013
Initial evaluation of automated treatment planning software
D Gintz, K Latifi, J Caudell, B Nelms, G Zhang, E Moros, V Feygelman
Journal of Applied Clinical Medical Physics 17 (3), 331-346, 2016
902016
Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy
BE Nelms, KH Rasmussen, WA Tomé
Journal of applied clinical medical physics 11 (2), 140-157, 2010
892010
Optimizing the accuracy of a helical diode array dosimeter: a comprehensive calibration methodology coupled with a novel virtual inclinometer
J Kozelka, J Robinson, B Nelms, G Zhang, D Savitskij, V Feygelman
Medical physics 38 (9), 5021-5032, 2011
832011
A method for a priori estimation of best feasible DVH for organs‐at‐risk: Validation for head and neck VMAT planning
S Ahmed, B Nelms, D Gintz, J Caudell, G Zhang, EG Moros, V Feygelman
Medical physics 44 (10), 5486-5497, 2017
582017
Radiation therapy plan dose perturbation system and method
BE Nelms, WE Simon
US Patent 7,945,022, 2011
542011
An analysis of an implantable dosimeter system for external beam therapy
RD Black, CW Scarantino, GG Mann, MS Anscher, RD Ornitz, BE Nelms
International Journal of Radiation Oncology* Biology* Physics 63 (1), 290-300, 2005
522005
Statistical variability and confidence intervals for planar dose QA pass rates
DW Bailey, BE Nelms, K Attwood, L Kumaraswamy, MB Podgorsak
Medical physics 38 (11), 6053-6064, 2011
512011
Statistical variability and confidence intervals for planar dose QA pass rates
DW Bailey, BE Nelms, K Attwood, L Kumaraswamy, MB Podgorsak
Medical physics 38 (11), 6053-6064, 2011
512011
The system can't perform the operation now. Try again later.
Articles 1–20