Hun Wi
Hun Wi
PhD student of Biomedical Engineering, Kyunghee University
Verified email at khu.ac.kr
TitleCited byYear
A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2
TI Oh, H Wi, DY Kim, PJ Yoo, EJ Woo
Physiological measurement 32 (7), 835, 2011
772011
Nanofiber web textile dry electrodes for long-term biopotential recording
TI Oh, S Yoon, TE Kim, H Wi, KJ Kim, EJ Woo, RJ Sadleir
IEEE transactions on biomedical circuits and systems 7 (2), 204-211, 2012
692012
Multi-frequency electrical impedance tomography system with automatic self-calibration for long-term monitoring
H Wi, H Sohal, AL McEwan, EJ Woo, TI Oh
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 8 (1), 119-128, 2013
682013
Performance evaluation of wideband bio-impedance spectroscopy using constant voltage source and constant current source
Y Mohamadou, TI Oh, H Wi, H Sohal, A Farooq, EJ Woo, AL McEwan
Measurement Science and Technology 23 (10), 105703, 2012
262012
Electrical impedance spectroscopy for electro-mechanical characterization of conductive fabrics
T Bera, Y Mohamadou, K Lee, H Wi, T Oh, E Woo, M Soleimani, J Seo
Sensors 14 (6), 9738-9754, 2014
172014
Bioimpedance spectroscopy tensor probe for anisotropic measurements
H Kwon, H Wi, B Karki, EJ Lee, A McEwan, EJ Woo, B Harrach, JK Seo, ...
Electronics letters 48 (20), 1253-1255, 2012
142012
Evaluation of a multi-electrode bioimpedance spectroscopy tensor probe to detect the anisotropic conductivity spectra of biological tissues
B Karki, H Wi, A McEwan, H Kwon, TI Oh, EJ Woo, JK Seo
Measurement Science and Technology 25 (7), 075702, 2014
132014
Fast conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) for RF ablation monitoring
OI Kwon, M Chauhan, HJ Kim, WC Jeong, H Wi, TI Oh, EJ Woo
International Journal of Hyperthermia 30 (7), 447-455, 2014
112014
Real‐time conductivity imaging of temperature and tissue property changes during radiofrequency ablation: An ex vivo model using weighted frequency difference
H Wi, AL McEwan, V Lam, HJ Kim, EJ Woo, TI Oh
Bioelectromagnetics 36 (4), 277-286, 2015
102015
Electrical impedance imaging system using FPGAs for flexibility and interoperability
H Sohal, H Wi, AL McEwan, EJ Woo, TI Oh
Biomedical engineering online 13 (1), 126, 2014
102014
An amplitude-to-time conversion technique suitable for multichannel data acquisition and bioimpedance imaging
JC Baeg, H Wi, TI Oh, AL McEwan, EJ Woo
IEEE transactions on biomedical circuits and systems 7 (3), 349-354, 2012
92012
Performance evaluation of KHU Mark2 parallel multi-frequency EIT system
DY Kim, H Wi, PJ Yoo, TI Oh, EJ Woo
Journal of Physics: Conference Series 224 (1), 012013, 2010
92010
Design of a microscopic electrical impedance tomography system for 3D continuous non-destructive monitoring of tissue culture
EJ Lee, H Wi, AL McEwan, A Farooq, H Sohal, EJ Woo, JK Seo, TI Oh
Biomedical engineering online 13 (1), 142, 2014
82014
High density trans-admittance mammography development and preliminary phantom tests
M Zhao, H Wi, AHM Kamal, AL McEwan, EJ Woo, TI Oh
Biomedical engineering online 11 (1), 75, 2012
82012
Design of a microscopic electrical impedance tomography system using two current injections
Q Liu, TI Oh, H Wi, EJ Lee, JK Seo, EJ Woo
Physiological measurement 32 (9), 1505, 2011
82011
Development of a prototype micro-EIT system using three sets of 15× 8 array electrodes
Q Liu, H Wi, TI Oh, EJ Woo, JK Seo
Journal of Physics: Conference Series 224 (1), 012161, 2010
62010
Conductivity image enhancement in MREIT using adaptively weighted spatial averaging filter
TI Oh, HJ Kim, WC Jeong, H Wi, OI Kwon, EJ Woo
Biomedical engineering online 13 (1), 87, 2014
42014
Expandable multi-frequency EIT system for clinical applications
H Wi, TE Kim, TI Oh, EJ Woo
Progress In Electromagnetics Research Symposium Proceedings, 49-52, 2012
42012
Modelling of electromagnetic field distribution for optimising electrode configurations in liver MR-based electrical impedance tomography
TI Oh, M Chauhan, S Sajib, JE Kim, WC Jeong, H Wi, HJ Kim, O Kwon, ...
Electronics Letters 50 (18), 1273-1275, 2014
32014
Continuous nondestructive monitoring method using the reconstructed three-dimensional conductivity images via GREIT for tissue engineering
S Ahn, H Wi, TI Oh, AL McEwan, SC Jun, EJ Woo
Journal of Applied Mathematics 2014, 2014
32014
The system can't perform the operation now. Try again later.
Articles 1–20