Follow
Andrew Wiles
Andrew Wiles
High Q Technologies
Verified email at alumni.uwaterloo.ca
Title
Cited by
Cited by
Year
Accuracy assessment and interpretation for optical tracking systems
AD Wiles, DG Thompson, DD Frantz
Medical Imaging 2004: Visualization, Image-Guided Procedures, and Display …, 2004
3912004
Accuracy assessment protocols for electromagnetic tracking systems
DD Frantz, AD Wiles, SE Leis, SR Kirsch
Physics in Medicine & Biology 48 (14), 2241, 2003
2902003
A statistical model for point-based target registration error with anisotropic fiducial localizer error
AD Wiles, A Likholyot, DD Frantz, TM Peters
IEEE transactions on medical imaging 27 (3), 378-390, 2008
1162008
A hardware and software protocol for the evaluation of electromagnetic tracker accuracy in the clinical environment: a multi-center study
E Wilson, Z Yaniv, H Zhang, C Nafis, E Shen, G Shechter, AD Wiles, ...
Medical Imaging 2007: Visualization and Image-Guided Procedures 6509, 960-970, 2007
622007
Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions
CA Linte, J Moore, AD Wiles, C Wedlake, TM Peters
Computer Aided Surgery 13 (2), 82-94, 2008
602008
Image guidance for spinal facet injections using tracked ultrasound
J Moore, C Clarke, D Bainbridge, C Wedlake, A Wiles, D Pace, T Peters
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2009: 12th …, 2009
522009
An augmented reality environment for image-guidance of off-pump mitral valve implantation
C Linte, AD Wiles, N Hill, J Moore, C Wedlake, G Guiraudon, D Jones, ...
Medical Imaging 2007: Visualization and Image-Guided Procedures 6509, 225-236, 2007
472007
Specifying 3D tracking system accuracy one manufacturer’s views
DD Frantz, SR Kirsch, AD Wiles
Bildverarbeitung für die Medizin 2004: Algorithmen—Systeme—Anwendungen …, 2004
272004
Improved statistical TRE model when using a reference frame
AD Wiles, TM Peters
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2007: 10th …, 2007
252007
Real-time estimation of FLE statistics for 3-D tracking with point-based registration
AD Wiles, TM Peters
IEEE transactions on medical imaging 28 (9), 1384-1398, 2009
242009
Integration of trans-esophageal echocardiography with magnetic tracking technology for cardiac interventions
JT Moore, AD Wiles, C Wedlake, D Bainbridge, B Kiaii, AL Trejos, R Patel, ...
Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling …, 2010
232010
Off-Pump Atrial Septal Defect Closure Using the Universal Cardiac Introducer®
GM Guiraudon, DL Jones, D Bainbridge, JT Moore, C Wedlake, C Linte, ...
Innovations 4 (1), 20-26, 2009
212009
Object identification accuracy under ultrasound enhanced virtual reality for minimally invasive cardiac surgery
AD Wiles, J Moore, CA Linte, C Wedlake, A Ahmad, TM Peters
Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling …, 2008
212008
Virtual Reality-Enhanced Ultrasound Guidance for Atrial Ablation: In vitro Epicardial Study
CA Linte, A Wiles, J Moore, C Wedlake, TM Peters
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2008: 11th …, 2008
152008
Targeting accuracy under model-to-subject misalignments in model-guided cardiac surgery
CA Linte, J Moore, AD Wiles, C Wedlake, TM Peters
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2009: 12th …, 2009
122009
Validation of four-dimensional ultrasound for targeting in minimally-invasive beating-heart surgery
DF Pace, AD Wiles, J Moore, C Wedlake, DG Gobbi, TM Peters
Medical Imaging 2009: Visualization, Image-Guided Procedures, and Modeling …, 2009
112009
In vitro cardiac catheter navigation via augmented reality surgical guidance
CA Linte, J Moore, A Wiles, J Lo, C Wedlake, TM Peters
Medical Imaging 2009: Visualization, Image-Guided Procedures, and Modeling …, 2009
112009
Navigation accuracy for an intracardiac procedure using virtual reality-enhanced ultrasound
AD Wiles, GM Guiraudon, J Moore, C Wedlake, CA Linte, DL Jones, ...
Medical imaging, 61410W-10, 2007
72007
From pre-operative cardiac modeling to intra-operative virtual environments for surgical guidance: an in vivo study
CA Linte, M Wierzbicki, J Moore, C Wedlake, AD Wiles, D Bainbridge, ...
Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling …, 2008
62008
Target tracking errors for 5D and 6D spatial measurement systems
AD Wiles, TM Peters
IEEE transactions on medical imaging 29 (3), 879-894, 2010
52010
The system can't perform the operation now. Try again later.
Articles 1–20