Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance-a population-based study A Harloff, H Mirzaee, T Lodemann, P Hagenlocher, T Wehrum, J Stuplich, ... Journal of Cardiovascular Magnetic Resonance 20 (1), 43, 2018 | 59 | 2018 |
Smoothness-increasing accuracy-conserving (SIAC) postprocessing for discontinuous Galerkin solutions over structured triangular meshes H Mirzaee, L Ji, JK Ryan, RM Kirby SIAM Journal on Numerical Analysis 49 (5), 1899-1920, 2011 | 55 | 2011 |
MRI‐based computational hemodynamics in patients with aortic coarctation using the lattice Boltzmann methods: clinical validation study H Mirzaee, T Henn, MJ Krause, L Goubergrits, C Schumann, ... Journal of Magnetic Resonance Imaging 45 (1), 139-146, 2017 | 42 | 2017 |
Efficient implementation of smoothness-increasing accuracy-conserving (SIAC) filters for discontinuous Galerkin solutions H Mirzaee, JK Ryan, RM Kirby Journal of Scientific Computing 52, 85-112, 2012 | 41 | 2012 |
Smoothness-increasing accuracy-conserving filters for discontinuous Galerkin solutions over unstructured triangular meshes H Mirzaee, J King, JK Ryan, RM Kirby SIAM Journal on Scientific Computing 35 (1), A212-A230, 2013 | 40 | 2013 |
Smoothness-increasing accuracy-conserving (SIAC) filtering for discontinuous Galerkin solutions: improved errors versus higher-order accuracy J King, H Mirzaee, JK Ryan, RM Kirby Journal of Scientific Computing 53 (1), 129-149, 2012 | 34 | 2012 |
Wall shear stress estimation in the aorta: Impact of wall motion, spatiotemporal resolution, and phase noise J Zimmermann, D Demedts, H Mirzaee, P Ewert, H Stern, C Meierhofer, ... Journal of Magnetic Resonance Imaging 48 (3), 718-728, 2018 | 33 | 2018 |
Smoothness-increasing accuracy-conserving (SIAC) filters for discontinuous Galerkin solutions: Application to structured tetrahedral meshes H Mirzaee, JK Ryan, RM Kirby Journal of Scientific Computing 58, 690-704, 2014 | 30 | 2014 |
Quantification of errors introduced in the numerical approximation and implementation of smoothness-increasing accuracy conserving (SIAC) filtering of discontinuous Galerkin … H Mirzaee, JK Ryan, RM Kirby Journal of Scientific Computing 45, 447-470, 2010 | 19 | 2010 |
Quantification of aortic stiffness in stroke patients using 4D flow MRI in comparison with transesophageal echocardiography T Wehrum, F Günther, M Kams, S Wendel, C Strecker, H Mirzaee, ... The international journal of cardiovascular imaging 34 (10), 1629-1636, 2018 | 11 | 2018 |
A software tool for the computation of arterial pulse wave velocity from flow-sensitive 4D MRI data J Drexl, H Mirzaee, A Harloff, M Hüllebrand, A Hennemuth, H Hahn Computing in Cardiology 2013, 559-562, 2013 | 8 | 2013 |
Noninvasive measurement of intravascular pressure gradients based on 3D anatomy and 4D flow image fusion H Mirzaee, A Hennemuth Proc ISMRM, 2753, 2015 | 3 | 2015 |
Smoothness-increasing accuracy-conserving filters (SIAC) for discontinuous Galerkin solutions H Mirzaee The University of Utah, 2013 | 2 | 2013 |
Background Correction and Stitching of Histological Plaque Images L Kaufhold, H Goebel, H Mirzaee, C Strecker, A Harloff, A Hennemuth Bildverarbeitung für die Medizin 2018: Algorithmen-Systeme-Anwendungen …, 2018 | 1 | 2018 |
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance A Harloff, H Mirzaee, T Lodemann, P Hagenlocher, T Wehrum, J Stuplich, ... | | 2018 |
Determination of aortic stiffness using 4D flow MRI:: a population-based study A Harloff Deutsche Nationalbibliothek, 2018 | | 2018 |
Patient-specific mesoscopic blood flow simulation: From image data to flow analysis H Mirzaee, S Meier, A Hennemuth, A Harloff, T Preusser The MATHCARD EU Project-www. mathcard. eu, Chia Laguna, Domus de Maria …, 2013 | | 2013 |
Comparison of Consistent Integration Versus Adaptive Quadrature For Taming Aliasing Errors H Mirzaee, C Eskilsson, SJ Sherwin, RM Kirby | | 2009 |
4D flow MRI based quantification of regional stiffness in the thoracic aorta in stroke patients compared to transesophageal echocardiography T Wehrum, F Günther, A Hennemuth, J Drexl, H Mirzaee, A Harloff | | |
4D-PC MRI Pressure Mapping for Therapy Planning of Coarctation of the Aorta A Hennemuth, C Schumann, M Neugebauer, H Mirzaee, S Nordmeyer, ... | | |