Follow
Ek T Tan
Title
Cited by
Cited by
Year
Accelerated diffusion spectrum imaging in the human brain using compressed sensing
MI Menzel, ET Tan, K Khare, JI Sperl, KF King, X Tao, CJ Hardy, ...
Magnetic Resonance in Medicine 66 (5), 1226-1233, 2011
1642011
Lightweight, compact, and high‐performance 3 T MR system for imaging the brain and extremities
TKF Foo, E Laskaris, M Vermilyea, M Xu, P Thompson, G Conte, ...
Magnetic resonance in medicine 80 (5), 2232-2245, 2018
1172018
Peripheral nerve stimulation characteristics of an asymmetric head‐only gradient coil compatible with a high‐channel‐count receiver array
SK Lee, JB Mathieu, D Graziani, J Piel, E Budesheim, E Fiveland, ...
Magnetic resonance in medicine 76 (6), 1939-1950, 2016
1112016
Peripheral nerve diffusion tensor imaging: overview, pitfalls, and future directions
T Jeon, MM Fung, KM Koch, ET Tan, DB Sneag
Journal of Magnetic Resonance Imaging 47 (5), 1171-1189, 2018
1002018
Improved correction for gradient nonlinearity effects in diffusion‐weighted imaging
ET Tan, L Marinelli, ZW Slavens, KF King, CJ Hardy
Journal of Magnetic Resonance Imaging 38 (2), 448-453, 2013
912013
High slew‐rate head‐only gradient for improving distortion in echo planar imaging: Preliminary experience
ET Tan, SK Lee, PT Weavers, D Graziani, JE Piel, Y Shu, J Huston III, ...
Journal of Magnetic Resonance Imaging 44 (3), 653-664, 2016
882016
Highly efficient head‐only magnetic field insert gradient coil for achieving simultaneous high gradient amplitude and slew rate at 3.0 T (MAGNUS) for brain microstructure imaging
TKF Foo, ET Tan, ME Vermilyea, Y Hua, EW Fiveland, JE Piel, K Park, ...
Magnetic resonance in medicine 83 (6), 2356-2369, 2020
842020
Gradient nonlinearity correction to improve apparent diffusion coefficient accuracy and standardization in the american college of radiology imaging network 6698 breast cancer …
DC Newitt, ET Tan, LJ Wilmes, TL Chenevert, J Kornak, L Marinelli, ...
Journal of Magnetic Resonance Imaging 42 (4), 908-919, 2015
672015
In vivo three-dimensional displacement of the distal radioulnar joint during resisted forearm rotation
SC Tay, RA Berger, K Tomita, ET Tan, KK Amrami, KN An
The Journal of hand surgery 32 (4), 450-458, 2007
572007
Gradient nonlinearity calibration and correction for a compact, asymmetric magnetic resonance imaging gradient system
S Tao, JD Trzasko, JL Gunter, PT Weavers, Y Shu, J Huston, SK Lee, ...
Physics in Medicine & Biology 62 (2), N18, 2016
472016
Peripheral nerve stimulation limits of a high amplitude and slew rate magnetic field gradient coil for neuroimaging
ET Tan, Y Hua, EW Fiveland, ME Vermilyea, JE Piel, KJ Park, VB Ho, ...
Magnetic resonance in medicine 83 (1), 352-366, 2020
392020
Improvement of peripheral nerve visualization using a deep learning-based MR reconstruction algorithm
KC Zochowski, ET Tan, EC Argentieri, B Lin, AJ Burge, SC Queler, ...
Magnetic Resonance Imaging 85, 186-192, 2022
332022
Diffusion kurtosis and quantitative susceptibility mapping MRI are sensitive to structural abnormalities in amyotrophic lateral sclerosis
T Welton, JJ Maller, RM Lebel, ET Tan, DB Rowe, SM Grieve
NeuroImage: Clinical 24, 101953, 2019
332019
Distortion correction in diffusion‐weighted imaging of the breast: Performance assessment of prospective, retrospective, and combined (prospective+ retrospective) approaches
I Hancu, SK Lee, K Hulsey, R Lenkinski, D Holland, JI Sperl, ET Tan
Magnetic resonance in medicine 78 (1), 247-253, 2017
332017
Evaluation of deep learning reconstructed high-resolution 3D lumbar spine MRI
S Sun, ET Tan, DN Mintz, M Sahr, Y Endo, J Nguyen, RM Lebel, ...
European Radiology 32 (9), 6167-6177, 2022
322022
Dynamic slice‐dependent shim and center frequency update in 3 T breast diffusion weighted imaging
SK Lee, ET Tan, A Govenkar, I Hancu
Magnetic resonance in medicine 71 (5), 1813-1818, 2014
322014
Brain tumor segmentation with symmetric texture and symmetric intensity-based decision forests
A Bianchi, JV Miller, ET Tan, A Montillo
2013 IEEE 10th International Symposium on Biomedical Imaging, 748-751, 2013
312013
Post-contrast 3D inversion recovery magnetic resonance neurography for evaluation of branch nerves of the brachial plexus
DB Sneag, SP Daniels, C Geannette, SC Queler, BQ Lin, C de Silva, ...
European Journal of Radiology 132, 109304, 2020
282020
Oscillating diffusion‐encoding with a high gradient‐amplitude and high slew‐rate head‐only gradient for human brain imaging
ET Tan, RY Shih, J Mitra, T Sprenger, Y Hua, C Bhushan, MA Bernstein, ...
Magnetic resonance in medicine 84 (2), 950-965, 2020
282020
MR neurography of peripheral nerve injury in the presence of orthopedic hardware: technical considerations
DB Sneag, KC Zochowski, ET Tan
Radiology 300 (2), 246-259, 2021
232021
The system can't perform the operation now. Try again later.
Articles 1–20