Roderick Loewen
Roderick Loewen
Lyncean Technologies, Inc.
Verified email at lynceantech.com
Title
Cited by
Cited by
Year
Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays
M Bech, O Bunk, C David, R Ruth, J Rifkin, R Loewen, R Feidenhans'l, ...
Journal of synchrotron radiation 16 (1), 43-47, 2009
1452009
Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source
S Schleede, FG Meinel, M Bech, J Herzen, K Achterhold, G Potdevin, ...
Proceedings of the National Academy of Sciences 109 (44), 17880-17885, 2012
1232012
Monochromatic computed tomography with a compact laser-driven X-ray source
K Achterhold, M Bech, S Schleede, G Potdevin, R Ruth, R Loewen, ...
Scientific reports 3, 1313, 2013
882013
Physics and technology of the Next Linear Collider: a report submitted to Snowmass' 96
S Kuhlman, JS Wurtele, PB Wilson, RF Koontz, J Rosenzweig, M Gintner, ...
791996
A compact light source: design and technical feasibility study of a laser-electron storage ring X-ray source
R Loewen
Stanford Linear Accelerator Center, Menlo Park, CA (US), 2004
782004
Proceedings of the 2001 Particle Accelerator Conference, Chicago
RJ Macek, A Browman, D Fitzgerald, R McCrady, F Merrill, M Plum, ...
IEEE, 2001
762001
X-ray phase-contrast tomography with a compact laser-driven synchrotron source
E Eggl, S Schleede, M Bech, K Achterhold, R Loewen, RD Ruth, F Pfeiffer
Proceedings of the National Academy of Sciences 112 (18), 5567-5572, 2015
622015
Apparatus, system, and method for high flux, compact compton x-ray source
J Rifkin, RJ Loewen, RD Ruth
US Patent 7,277,526, 2007
402007
The generation of 400-MW RF pulses at X-band using resonant delay lines
SG Tantawi, RJ Loewen, CD Nantista, AE Vlieks
IEEE Transactions on Microwave Theory and Techniques 47 (12), 2539-2546, 1999
401999
International study group progress report on linear collider development
CE Adolphsen, J De Lamare, G Caryotakis, L Keller, TW Markiewicz, ...
KEK, 2000
382000
Diagnosing and mapping pulmonary emphysema on x-ray projection images: incremental value of grating-based x-ray dark-field imaging
FG Meinel, F Schwab, S Schleede, M Bech, J Herzen, K Achterhold, ...
PloS one 8 (3), 2013
362013
Multimodal hard X-ray imaging of a mammography phantom at a compact synchrotron light source
S Schleede, M Bech, K Achterhold, G Potdevin, M Gifford, R Loewen, ...
Journal of synchrotron radiation 19 (4), 525-529, 2012
352012
Computer-aided tuning of charged particle accelerators
S Hanna, R Loewen
US Patent 6,498,444, 2002
352002
An algebraic iterative reconstruction technique for differential X-ray phase-contrast computed tomography
J Fu, S Schleede, R Tan, L Chen, M Bech, K Achterhold, M Gifford, ...
Zeitschrift für Medizinische Physik 23 (3), 186-193, 2013
302013
SLAC/CERN high gradient tests of an X-band accelerating section
JW Wang, GA Loew, RJ Loewen, RD Ruth, AE Vlieks, I Wilson, ...
Proceedings Particle Accelerator Conference 1, 653-655, 1995
291995
Comparison of contrast-to-noise ratios of transmission and dark-field signal in grating-based X-ray imaging for healthy murine lung tissue
F Schwab, S Schleede, D Hahn, M Bech, J Herzen, S Auweter, ...
Zeitschrift für Medizinische Physik 23 (3), 236-242, 2013
272013
Processing Studies of X-band Accelerator Structures at the NLCTA
C Adolphsen, W Baumgartner, K Jobe, F Le Pimpec, R Loewen, ...
PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No …, 2001
272001
Physics and Technology of the Next Linear Collider
S Kuhlman
hepex9605011, 1996
261996
X-ray structure determination of the glycine cleavage system protein H of Mycobacterium tuberculosis using an inverse Compton synchrotron X-ray source
J Abendroth, MS McCormick, TE Edwards, B Staker, R Loewen, M Gifford, ...
Journal of structural and functional genomics 11 (1), 91-100, 2010
252010
Configuring queues based on a given parameter
GP Merrill, SW Zagorianakos
US Patent 6,993,602, 2006
24*2006
The system can't perform the operation now. Try again later.
Articles 1–20