Follow
Sigal Portnoy
Sigal Portnoy
Verified email at tauex.tau.ac.il - Homepage
Title
Cited by
Cited by
Year
Internal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputee
S Portnoy, Z Yizhar, N Shabshin, Y Itzchak, A Kristal, Y Dotan-Marom, ...
Journal of biomechanics 41 (9), 1897-1909, 2008
1802008
Stress relaxation of porcine gluteus muscle subjected to sudden transverse deformation as related to pressure sore modeling
A Palevski, I Glaich, S Portnoy, E Linder-Ganz, A Gefen
1382006
Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting
S Portnoy, G Yarnitzky, Z Yizhar, A Kristal, U Oppenheim, I Siev-Ner, ...
Annals of biomedical engineering 35, 120-135, 2007
1062007
Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation
JJ Elsner, S Portnoy, G Zur, F Guilak, A Shterling, E Linder-Ganz
952010
The association of ankle dorsiflexion range of motion with hip and knee kinematics during the lateral step-down test
A Rabin, S Portnoy, Z Kozol
Journal of orthopaedic & sports physical therapy 46 (11), 1002-1009, 2016
872016
Patient-specific analyses of deep tissue loads post transtibial amputation in residual limbs of multiple prosthetic users
S Portnoy, I Siev-Ner, N Shabshin, A Kristal, Z Yizhar, A Gefen
Journal of biomechanics 42 (16), 2686-2693, 2009
862009
Surgical and morphological factors that affect internal mechanical loads in soft tissues of the transtibial residuum
S Portnoy, I Siev-Ner, Z Yizhar, A Kristal, N Shabshin, A Gefen
Annals of biomedical engineering 37, 2583-2605, 2009
732009
Outdoor dynamic subject-specific evaluation of internal stresses in the residual limb: Hydraulic energy-stored prosthetic foot compared to conventional energy-stored prosthetic …
S Portnoy, A Kristal, A Gefen, I Siev-Ner
Gait & posture 35 (1), 121-125, 2012
722012
Real-time subject-specific analyses of dynamic internal tissue loads in the residual limb of transtibial amputees
S Portnoy, J van Haare, RPJ Geers, A Kristal, I Siev-Ner, HAM Seelen, ...
Medical engineering & physics 32 (4), 312-323, 2010
452010
MRI-based characterization of bone anatomy in the human knee for size matching of a medial meniscal implant
JJ Elsner, S Portnoy, F Guilak, A Shterling, E Linder-Ganz
422010
The correlation between upper extremity musculoskeletal symptoms and joint kinematics, playing habits and hand span during playing among piano students
Y Kaufman-Cohen, S Portnoy, R Sopher, L Mashiach, L Baruch-Halaf, ...
PloS one 13 (12), e0208788, 2018
362018
Hemorrhagic versus ischemic stroke: Who can best benefit from blended conventional physiotherapy with robotic-assisted gait therapy?
F Dierick, M Dehas, JL Isambert, S Injeyan, AF Bouche, Y Bleyenheuft, ...
PloS one 12 (6), e0178636, 2017
352017
The association between visual assessment of quality of movement and three-dimensional analysis of pelvis, hip, and knee kinematics during a lateral step down test
A Rabin, S Portnoy, Z Kozol
The Journal of Strength & Conditioning Research 30 (11), 3204-3211, 2016
342016
Visuomotor behaviors and performance in a dual-task paradigm with and without vibrotactile feedback when using a myoelectric controlled hand
E Raveh, J Friedman, S Portnoy
Assistive Technology 30 (5), 274-280, 2018
332018
Effects of sitting postures on risks for deep tissue injury in the residuum of a transtibial prosthetic-user: a biomechanical case study
S Portnoy, I Siev-Ner, N Shabshin, A Gefen
Computer methods in biomechanics and biomedical engineering 14 (11), 1009-1019, 2011
332011
Adding vibrotactile feedback to a myoelectric-controlled hand improves performance when online visual feedback is disturbed
E Raveh, S Portnoy, J Friedman
Human movement science 58, 32-40, 2018
312018
Postural control of individuals with chronic stroke compared to healthy participants: Timed-Up-and-Go, Functional Reach Test and center of pressure movement
S Portnoy, S Reif, T Mendelboim, D Rand
Eur J Phys Rehabil Med 53 (5), 685-93, 2017
302017
Prevention of genu recurvatum in poststroke patients using a hinged soft knee orthosis
S Portnoy, A Frechtel, E Raveh, I Schwartz
PM&R 7 (10), 1042-1051, 2015
302015
Myoelectric prosthesis users improve performance time and accuracy using vibrotactile feedback when visual feedback is disturbed
E Raveh, S Portnoy, J Friedman
Archives of physical medicine and rehabilitation 99 (11), 2263-2270, 2018
242018
Real-time finite element monitoring of internal stresses in the buttock during wheelchair sitting to prevent pressure sores: verification and phantom results
E Linder-Ganz, G Yarnitzky, S Portnoy, Z Yizhar, A Gefen
II International Conference on Omputational Bioengineering. H. Rodrigues et …, 2005
242005
The system can't perform the operation now. Try again later.
Articles 1–20