Chen-Yu Huang
Chen-Yu Huang
Hong Kong Sanatorium & Hospital
Verified email at hksh.com
Title
Cited by
Cited by
Year
The first clinical treatment with kilovoltage intrafraction monitoring (KIM): a real‐time image guidance method
PJ Keall, J Aun Ng, R O'Brien, E Colvill, CY Huang, P Rugaard Poulsen, ...
Medical physics 42 (1), 354-358, 2015
652015
Six degrees-of-freedom prostate and lung tumor motion measurements using kilovoltage intrafraction monitoring
CY Huang, JN Tehrani, JA Ng, J Booth, P Keall
International Journal of Radiation Oncology* Biology* Physics 91 (2), 368-375, 2015
532015
Real-time 3D image guidance using a standard LINAC: measured motion, accuracy, and precision of the first prospective clinical trial of kilovoltage intrafraction monitoring …
PJ Keall, JA Ng, P Juneja, RT O'Brien, CY Huang, E Colvill, V Caillet, ...
International Journal of Radiation Oncology* Biology* Physics 94 (5), 1015-1021, 2016
442016
Microdosimetry for targeted alpha therapy of cancer
CY Huang, S Guatelli, BM Oborn, BJ Allen
Computational and mathematical methods in medicine 2012, 2012
352012
The first clinical implementation of a real-time six degree of freedom target tracking system during radiation therapy based on Kilovoltage Intrafraction Monitoring (KIM)
DT Nguyen, R O'Brien, JH Kim, CY Huang, L Wilton, P Greer, K Legge, ...
Radiotherapy and Oncology 123 (1), 37-42, 2017
332017
Targeted alpha anticancer therapies: update and future prospects
BJ Allen, CY Huang, RA Clarke
Biologics: targets & therapy 8, 255, 2014
322014
Optimizing radioimmunoconjugate delivery in the treatment of solid tumor
CY Huang, MH Pourgholami, BJ Allen
Cancer treatment reviews 38 (7), 854-860, 2012
292012
Markerless tumor tracking using short kilovoltage imaging arcs for lung image-guided radiotherapy
CC Shieh, PJ Keall, Z Kuncic, CY Huang, I Feain
Physics in medicine & biology 60 (24), 9437, 2015
252015
Monte Carlo calculation of the maximum therapeutic gain of tumor antivascular alpha therapy
CY Huang, BM Oborn, S Guatelli, BJ Allen
Medical physics 39 (3), 1282-1288, 2012
232012
Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT
JA Ng, JT Booth, RT O'Brien, E Colvill, CY Huang, PR Poulsen, PJ Keall
Medical physics 41 (11), 111712, 2014
222014
Quantifying the accuracy and precision of a novel real-time 6 degree-of-freedom kilovoltage intrafraction monitoring (KIM) target tracking system
JH Kim, DT Nguyen, CY Huang, T Fuangrod, V Caillet, R O’brien, ...
Physics in Medicine & Biology 62 (14), 5744, 2017
112017
Background dose for systemic targeted alpha therapy
CY Huang, S Guatelli, B Oborn, BJ Allen
92011
The accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom prostate motion measurements during patient treatments
JH Kim, DT Nguyen, JT Booth, CY Huang, T Fuangrod, P Poulsen, ...
Radiotherapy and Oncology 126 (2), 236-243, 2018
82018
Functional imaging equivalence and proof of concept for image-guided adaptive radiotherapy with fixed gantry and rotating couch
I Feain, CC Shieh, P White, R O'Brien, S Fisher, W Counter, P Lazarakis, ...
Advances in Radiation Oncology 1 (4), 365-372, 2016
82016
Performance assessment of a programmable five degrees-of-freedom motion platform for quality assurance of motion management techniques in radiotherapy
CY Huang, P Keall, A Rice, E Colvill, JA Ng, JT Booth
Australasian physical & engineering sciences in medicine 40 (3), 643-649, 2017
72017
Targeted alpha therapy: from alpha to omega
BJ Allen, R Clarke, C Huang
32013
Sub-mm accuracy results measured from the first prospective clinical trial of a novel real-time IGRT system, Kilovoltage Intrafraction Monitoring (KIM)
P Keall, JA Ng, V Caillet, CY Huang, E Colvill, E Simpson, PR Poulsen, ...
International Journal of Radiation Oncology• Biology• Physics 93 (3), S192-S193, 2015
22015
First clinical implementation of audiovisual biofeedback in liver cancer stereotactic body radiation therapy
S Pollock, R Tse, D Martin, L McLean, G Cho, R Hill, S Pickard, P Aston, ...
Journal of medical imaging and radiation oncology 59 (5), 654-656, 2015
22015
EP-1490: Accuracy results from the first clinical trial of a new real-time IGRT system, Kilovoltage Intrafraction Monitoring
PJ Keall, JA Ng, CY Huang, E Colvill, PR Poulsen, E Simpson, ...
Radiotherapy and Oncology 115, S810, 2015
22015
SU‐E‐J‐03: A Comprehensive Comparison Between Alpha and Beta Emitters for Cancer Radioimmunotherapy
CY Huang, S Guatelli, B Oborn, B Allen
Medical Physics 41 (6Part6), 154-155, 2014
22014
The system can't perform the operation now. Try again later.
Articles 1–20