Zhongjun J Wu, PhD
Zhongjun J Wu, PhD
Professor of Surgery, Universit of Maryland, Baltimore
Verified email at smail.umaryland.edu - Homepage
Title
Cited by
Cited by
Year
The use of computational fluid dynamics in the development of ventricular assist devices
KH Fraser, ME Taskin, BP Griffith, ZJ Wu
Medical engineering & physics 33 (3), 263-280, 2011
2322011
A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index
KH Fraser, T Zhang, ME Taskin, BP Griffith, ZJ Wu
Journal of biomechanical engineering 134 (8), 2012
2222012
Computational fluid dynamics as a development tool for rotary blood pumps
GW Burgreen, JF Antaki, ZJ Wu, AJ Holmes
Artificial organs 25 (5), 336-340, 2001
1702001
Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
J Zhang, B Gellman, A Koert, KA Dasse, RJ Gilbert, BP Griffith, ZJ Wu
Artificial organs 30 (3), 168-177, 2006
1442006
Evaluation of Eulerian and Lagrangian models for hemolysis estimation
ME Taskin, KH Fraser, T Zhang, C Wu, BP Griffith, ZJ Wu
ASAIO journal 58 (4), 363-372, 2012
1312012
Blood soluble drag‐reducing polymers prevent lethality from hemorrhagic shock in acute animal experiments
MV Kameneva, ZJ Wu, A Uraysh, B Repko, KN Litwak, TR Billiar, MP Fink, ...
Biorheology 41 (1), 53-64, 2004
1282004
Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves
DK Hildebrand, ZJ Wu, JE Mayer, MS Sacks
Annals of biomedical engineering 32 (8), 1039-1049, 2004
1252004
Study of flow‐induced hemolysis using novel couette‐type blood‐shearing devices
T Zhang, ME Taskin, HB Fang, A Pampori, R Jarvik, BP Griffith, ZJ Wu
Artificial organs 35 (12), 1180-1186, 2011
1192011
Blood-aggregating hydrogel particles for use as a hemostatic agent
AM Behrens, MJ Sikorski, T Li, ZJ Wu, BP Griffith, P Kofinas
Acta biomaterialia 10 (2), 701-708, 2014
1042014
Ambulatory veno-venous extracorporeal membrane oxygenation: innovation and pitfalls
JP Garcia, ZN Kon, C Evans, Z Wu, AT Iacono, B McCormick, BP Griffith
The Journal of thoracic and cardiovascular surgery 142 (4), 755-761, 2011
1042011
Computational characterization of flow and hemolytic performance of the UltraMag blood pump for circulatory support
ME Taskin, KH Fraser, T Zhang, B Gellman, A Fleischli, KA Dasse, ...
Artificial organs 34 (12), 1099-1113, 2010
842010
Smooth muscle cell hypertrophy of renal cortex arteries with chronic continuous flow left ventricular assist
S Kihara, KN Litwak, L Nichols, P Litwak, MV Kameneva, Z Wu, ...
The Annals of thoracic surgery 75 (1), 178-183, 2003
642003
Occluder closing behavior: a key factor in mechanical heart valve cavitation.
ZJ Wu, Y Wang, NH Hwang
The Journal of heart valve disease 3, S25-33; discussion S33, 1994
591994
Paradoxical Effect of Nonphysiological Shear Stress on Platelets and v on W illebrand Factor
Z Chen, NK Mondal, J Ding, SC Koenig, MS Slaughter, ZJ Wu
Artificial organs 40 (7), 659-668, 2016
582016
Characterization of membrane blood oxygenation devices using computational fluid dynamics
J Zhang, TDC Nolan, T Zhang, BP Griffith, ZJ Wu
Journal of Membrane Science 288 (1-2), 268-279, 2007
582007
Microscopic investigation of erythrocyte deformation dynamics
R Zhao, JF Antaki, T Naik, TN Bachman, MV Kameneva, ZJ Wu
Biorheology 43 (6), 747-765, 2006
572006
Computational fluid dynamics analysis of thrombosis potential in left ventricular assist device drainage cannulae
KH Fraser, T Zhang, ME Taskin, BP Griffith, ZJ Wu
ASAIO journal (American Society for Artificial Internal Organs: 1992) 56 (3 …, 2010
552010
Touch down of blood pump impellers
CD Capone, RC Dempsey, MS Heilman, SA Kolenik, DR Moore, ...
US Patent 6,761,532, 2004
482004
Drag reducing polymers improve tissue perfusion via modification of the RBC traffic in microvessels
JN Marhefka, R Zhao, ZJ Wu, SS Velankar, JF Antaki, MV Kameneva
Biorheology 46 (4), 281-292, 2009
472009
Shear-induced platelet receptor shedding by non-physiological high shear stress with short exposure time: glycoprotein Ibα and glycoprotein VI
Z Chen, NK Mondal, J Ding, J Gao, BP Griffith, ZJ Wu
Thrombosis research 135 (4), 692-698, 2015
462015
The system can't perform the operation now. Try again later.
Articles 1–20