Stuart Crozier
Stuart Crozier
Verified email at itee.uq.edu.au
Title
Cited by
Cited by
Year
Apparent fibre density: a novel measure for the analysis of diffusion-weighted magnetic resonance images
D Raffelt, JD Tournier, S Rose, GR Ridgway, R Henderson, S Crozier, ...
Neuroimage 59 (4), 3976-3994, 2012
3102012
The Australian magnetic resonance imaging–linac program
PJ Keall, M Barton, S Crozier
Seminars in radiation oncology 24 (3), 203-206, 2014
2572014
Automatic segmentation and quantitative analysis of the articular cartilages from magnetic resonance images of the knee
J Fripp, S Crozier, SK Warfield, S Ourselin
IEEE transactions on medical imaging 29 (1), 55-64, 2009
1802009
Mask scoring r-cnn
Z Huang, L Huang, Y Gong, C Huang, X Wang
Proceedings of the IEEE conference on computer vision and pattern …, 2019
1552019
Gradient-coil design by stimulated annealing
S Crozier, DM Doddrell
Journal of magnetic resonance. Series A (Print) 103 (3), 354-357, 1993
1321993
Automatic segmentation of the bone and extraction of the bone–cartilage interface from magnetic resonance images of the knee
J Fripp, S Crozier, SK Warfield, S Ourselin
Physics in Medicine & Biology 52 (6), 1617, 2007
1272007
Implementation and investigation of U-shaped aperture UWB antenna with dual band-notched characteristics
HJ Zhou, BH Sun, QZ Liu, JY Deng
Electronics letters 44 (24), 1387-1388, 2008
1232008
Symmetric diffeomorphic registration of fibre orientation distributions
D Raffelt, JD Tournier, J Fripp, S Crozier, A Connelly, O Salvado
NeuroImage 56 (3), 1171-1180, 2011
1182011
Determining complicated winding patterns for shim coils using stream functions and the target‐field method
MA Brideson, LK Forbes, S Crozier
Concepts in Magnetic Resonance: an Educational Journal 14 (1), 9-18, 2002
1182002
Automated detection, 3D segmentation and analysis of high resolution spine MR images using statistical shape models
A Neubert, J Fripp, C Engstrom, R Schwarz, L Lauer, O Salvado, ...
Physics in Medicine & Biology 57 (24), 8357, 2012
1052012
Electromagnetic fields inside a lossy, multilayered spherical head phantom excited by MRI coils: models and methods
F Liu, S Crozier
Physics in Medicine & Biology 49 (10), 1835, 2004
892004
An ultra wideband microwave imaging system for breast cancer detection
WC Khor, ME Bialkowski, A Abbosh, N Seman, S Crozier
IEICE Transactions on Communications 90 (9), 2376-2381, 2007
852007
Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means
Y Gal, AJH Mehnert, AP Bradley, K McMahon, D Kennedy, S Crozier
IEEE transactions on medical imaging 29 (2), 302-310, 2009
842009
On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRI
F Liu, H Zhao, S Crozier
IEEE transactions on biomedical engineering 50 (7), 804-815, 2003
832003
Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments
MA Fuentes, A Trakic, SJ Wilson, S Crozier
IEEE Transactions on Biomedical Engineering 55 (4), 1355-1364, 2008
812008
Numerical evaluation of the fields induced by body motion in or near high-field MRI scanners
S Crozier, F Liu
Progress in biophysics and molecular biology 87 (2-3), 267-278, 2005
802005
Quadrature detection in F1 induced by pulsed field gradients
IM Brereton, S Crozier, J Field, DM Doddrell
Journal of Magnetic Resonance (1969) 93 (1), 54-62, 1991
771991
A novel target-field method for finite-length magnetic resonance shim coils: II. Tesseral shims
LK Forbes, S Crozier
Journal of physics D: Applied physics 35 (9), 839, 2002
742002
Future of medical physics: real‐time MRI‐guided proton therapy
BM Oborn, S Dowdell, PE Metcalfe, S Crozier, R Mohan, PJ Keall
Medical physics 44 (8), e77-e90, 2017
732017
Calculation of electric fields induced by body and head motion in high-field MRI
F Liu, H Zhao, S Crozier
Journal of Magnetic Resonance 161 (1), 99-107, 2003
722003
The system can't perform the operation now. Try again later.
Articles 1–20