Stuart Crozier
Stuart Crozier
Verified email at itee.uq.edu.au
TitleCited byYear
Apparent fibre density: a novel measure for the analysis of diffusion-weighted magnetic resonance images
D Raffelt, JD Tournier, S Rose, GR Ridgway, R Henderson, S Crozier, ...
Neuroimage 59 (4), 3976-3994, 2012
2562012
The Australian magnetic resonance imaging–linac program
PJ Keall, M Barton, S Crozier
Seminars in radiation oncology 24 (3), 203-206, 2014
2072014
Automatic segmentation and quantitative analysis of the articular cartilages from magnetic resonance images of the knee
J Fripp, S Crozier, SK Warfield, S Ourselin
IEEE transactions on medical imaging 29 (1), 55-64, 2009
1572009
Gradient-coil design by simulated annealing
S Crozier, DM Doddrell
Journal of Magnetic Resonance, Series A 103 (3), 354-357, 1993
1301993
Determining complicated winding patterns for shim coils using stream functions and the target‐field method
MA Brideson, LK Forbes, S Crozier
Concepts in Magnetic Resonance: An Educational Journal 14 (1), 9-18, 2002
1132002
Automatic segmentation of the bone and extraction of the bone–cartilage interface from magnetic resonance images of the knee
J Fripp, S Crozier, SK Warfield, S Ourselin
Physics in Medicine & Biology 52 (6), 1617, 2007
1102007
Automated detection, 3D segmentation and analysis of high resolution spine MR images using statistical shape models
A Neubert, J Fripp, C Engstrom, R Schwarz, L Lauer, O Salvado, ...
Physics in Medicine & Biology 57 (24), 8357, 2012
902012
Electromagnetic fields inside a lossy, multilayered spherical head phantom excited by MRI coils: models and methods
F Liu, S Crozier
Physics in Medicine & Biology 49 (10), 1835, 2004
892004
Symmetric diffeomorphic registration of fibre orientation distributions
D Raffelt, JD Tournier, J Fripp, S Crozier, A Connelly, O Salvado
NeuroImage 56 (3), 1171-1180, 2011
862011
An ultra wideband microwave imaging system for breast cancer detection
WC Khor, ME Bialkowski, A Abbosh, N Seman, S Crozier
IEICE Transactions on Communications 90 (9), 2376-2381, 2007
822007
On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRI
F Liu, H Zhao, S Crozier
IEEE Transactions on Biomedical Engineering 50 (7), 804-815, 2003
812003
Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments
MA Fuentes, A Trakic, SJ Wilson, S Crozier
IEEE Transactions on Biomedical Engineering 55 (4), 1355-1364, 2008
792008
Numerical evaluation of the fields induced by body motion in or near high-field MRI scanners
S Crozier, F Liu
Progress in biophysics and molecular biology 87 (2-3), 267-278, 2005
782005
Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means
Y Gal, AJH Mehnert, AP Bradley, K McMahon, D Kennedy, S Crozier
IEEE transactions on medical imaging 29 (2), 302-310, 2009
762009
Quadrature detection in F1 induced by pulsed field gradients
IM Brereton, S Crozier, J Field, DM Doddrell
Journal of Magnetic Resonance (1969) 93 (1), 54-62, 1991
761991
Calculation of electric fields induced by body and head motion in high-field MRI
F Liu, H Zhao, S Crozier
Journal of Magnetic Resonance 161 (1), 99-107, 2003
692003
A novel target-field method for finite-length magnetic resonance shim coils: II. Tesseral shims
LK Forbes, S Crozier
Journal of physics D: Applied physics 35 (9), 839, 2002
682002
The design of transverse gradient coils of restricted length by simulated annealing
S Crozier, LK Forbes, DM Doddrell
Journal of Magnetic Resonance, Series A 107 (1), 126-128, 1994
681994
Analysis of cardiac ventricular wall motion based on a three-dimensional electromechanical biventricular model
L Xia, M Huo, Q Wei, F Liu, S Crozier
Physics in Medicine & Biology 50 (8), 1901, 2005
652005
Rapid computation of static fields produced by thick circular solenoids
LK Forbes, S Crozier, DM Doddrell
IEEE Transactions on Magnetics 33 (5), 4405-4410, 1997
601997
The system can't perform the operation now. Try again later.
Articles 1–20