EPID dosimetry for pretreatment quality assurance with two commercial systems DW Bailey, L Kumaraswamy, M Bakhtiari, HK Malhotra, MB Podgorsak Journal of applied clinical medical physics 13 (4), 82-99, 2012 | 107 | 2012 |
Using an EPID for patient‐specific VMAT quality assurance M Bakhtiari, L Kumaraswamy, DW Bailey, S De Boer, HK Malhotra, ... Medical physics 38 (3), 1366-1373, 2011 | 103 | 2011 |
A pilot study of stereotactic body radiation therapy combined with cytoreductive nephrectomy for metastatic renal cell carcinoma AK Singh, TB Winslow, MH Kermany, V Goritz, L Heit, A Miller, ... Clinical Cancer Research 23 (17), 5055-5065, 2017 | 73 | 2017 |
Statistical variability and confidence intervals for planar dose QA pass rates DW Bailey, BE Nelms, K Attwood, L Kumaraswamy, MB Podgorsak Medical physics 38 (11), 6053-6064, 2011 | 52 | 2011 |
Spatial variation of dosimetric leaf gap and its impact on dose delivery LK Kumaraswamy, JD Schmitt, DW Bailey, ZZ Xu, MB Podgorsak Medical Physics 41 (11), 111711, 2014 | 29 | 2014 |
An effective correction algorithm for off‐axis portal dosimetry errors DW Bailey, L Kumaraswamy, MB Podgorsak Medical physics 36 (9Part1), 4089-4094, 2009 | 27 | 2009 |
A fully electronic intensity-modulated radiation therapy quality assurance (IMRT QA) process implemented in a network comprised of independent treatment planning, record and … D Bailey, L Kumaraswamy, M Podgorsak Radiology and oncology 44 (2), 124-130, 2010 | 22 | 2010 |
Comparison of hybrid volumetric modulated arc therapy (VMAT) technique and double arc VMAT technique in the treatment of prostate cancer C Amaloo, DP Nazareth, LK Kumaraswamy Radiology and oncology 49 (3), 291-298, 2015 | 13 | 2015 |
Dosimetric evaluation of incorporating the revised V4. 0 calibration protocol for breast intraoperative radiotherapy with the INTRABEAM system MY Shaikh, J Burmeister, R Scott, LK Kumaraswamy, A Nalichowski, ... Journal of applied clinical medical physics 21 (2), 50-59, 2020 | 11 | 2020 |
Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT) Z Xu, IZ Wang, LK Kumaraswamy, MB Podgorsak Radiology and oncology 50 (1), 121-128, 2016 | 11 | 2016 |
Automatic verification of step‐and‐shoot IMRT field segments using portal imaging MK Woo, AW Lightstone, G Shan, L Kumaraswamy, Y Li Medical Physics 30 (3), 348-351, 2003 | 11 | 2003 |
A two‐dimensional matrix correction for off‐axis portal dose prediction errors DW Bailey, L Kumaraswamy, M Bakhtiari, MB Podgorsak Medical physics 40 (5), 051704, 2013 | 10 | 2013 |
The MapCHECK measurement uncertainty function and its effect on planar dose pass rates DW Bailey, JD Spaans, LK Kumaraswamy, MB Podgorsak Journal of Applied Clinical Medical Physics 17 (2), 165-173, 2016 | 9 | 2016 |
Minimally invasive rib-sparing video-assisted thoracoscopic surgery resections with high-dose-rate intraoperative brachytherapy for selected chest wall tumors DJ Bourgeois III, S Yendamuri, M Hennon, J Gomez, H Malhotra, ... Practical radiation oncology 6 (6), e329-e335, 2016 | 8 | 2016 |
Evaluation of fluence‐based dose delivery incorporating the spatial variation of dosimetric leaf gap (DLG) LK Kumaraswamy, Z Xu, DW Bailey, JD Schmitt, MB Podgorsak Journal of Applied Clinical Medical Physics 17 (1), 12-21, 2016 | 6 | 2016 |
Correlating the depth of compensation to the 3-D shape of the breast to achieve homogeneous dose distribution using the electronic tissue compensation treatment technique AH Alghufaili, L Shanmugarajah, LK Kumaraswamy Medical Dosimetry 44 (1), 30-34, 2019 | 4 | 2019 |
Recommendation of fiducial marker implantation for better target tracking using MV imager in prostate radiotherapy T Ma, J Kilian‐Meneghin, LK Kumaraswamy Journal of Applied Clinical Medical Physics 19 (5), 389-397, 2018 | 4 | 2018 |
Accuracy of one algorithm used to modify a planned DVH with data from actual dose delivery T Ma, MB Podgorsak, LK Kumaraswamy Journal of Applied Clinical Medical Physics 17 (5), 273-282, 2016 | 4 | 2016 |
SU‐GG‐T‐169: comparison of the efficacy of MapCHECK and portal dosimetry in the pretreatment QA of IMRT treatment plans J Liu, Z Wang, L Kumaraswamy, D Nazareth, M Podgorsak, H Malhotra Medical Physics 35 (6Part11), 2764-2765, 2008 | 4 | 2008 |
An introduction to key performance indicators for medical physicists DJ DiCostanzo, LK Kumaraswamy, J Shuman, DC Pavord, Y Hu, ... Journal of Applied Clinical Medical Physics 23 (8), e13718, 2022 | 2 | 2022 |